Vidas brahms pct kit

Manufactured by bioMérieux
Sourced in France

The VIDAS BRAHMS PCT kit is a diagnostic test used to measure the level of procalcitonin (PCT) in patient samples. PCT is a biomarker that can help assess the risk of severe bacterial infections and sepsis. The VIDAS BRAHMS PCT kit provides a quantitative measurement of PCT concentration, which can aid in the diagnosis and management of these conditions.

Automatically generated - may contain errors

5 protocols using vidas brahms pct kit

1

Serum Biomarkers in H1N1 Infection

Check if the same lab product or an alternative is used in the 5 most similar protocols
Venous blood samples were collected from H1N1‐infected patients upon admission. Serum PCT levels were determined using an enzyme‐linked fluorescence analysis (ELFA, VIDAS BRAHMS PCT kit, bioMerieux SA, Marcy‐l'Etoile, France). Serum CRP levels were determined using a BNPProSpec automatic protein analyzer (Dade Behring BN Prospec, Deerfield, IL, USA),18 and WBC counts were analyzed by using a Sysmex XE‐2100 hematology analyzer (Sysmex, Kobe, Japan).
+ Open protocol
+ Expand
2

Quantification of Serum CRP and PCT

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum C-reactive protein (CRP) was quantified via scattering turbidimetry (CardioPhase hsCRP, Siemens, Munich, Germany), and procalcitonin (PCT) was quantified using an enzyme-linked fluorescence analysis kit (VIDAS B.R.A.H.M.S. PCT kit, bioMerieux SA, Marcy l’Etoile, France), according to the manufacturers’ instructions.
+ Open protocol
+ Expand
3

Biomarker Measurement Techniques

Check if the same lab product or an alternative is used in the 5 most similar protocols
PCT was measured using an enzyme-linked fluorescence analysis kit (ELFA, VIDAS BRAHMS PCT kit, bioMerieux SA, France). sTREM-1 was determined using a double antibody sandwich ELISA (Quantikine Human TREM-1 Immunoassay ELISA Kit, R & D Systems, Minneapolis, MN, USA). NT-pro-BNP was measured with an available immunoassay analyzer (Elecsys 2010; Roche Diagnostics, Mannheim, Germany). CRP was determined using scattering using a nephelometric assay (Dade-Behring, SA Paris, France). IL-6 and IL-10 were determined using ELISA (IMMULITE; Diagnostics Products Corporation, Los Angeles, CA). All assays were performed according to the manufacturer's instructions.
+ Open protocol
+ Expand
4

Biomarkers in Pediatric ICU Patients

Check if the same lab product or an alternative is used in the 5 most similar protocols
We recorded the 24 h BLA values of the 90 patients at the time of admission into the PICU. BLA was measured with Vitros 250 full automation dipsticks analyzer manufactured by Johnson & Johnson (New Brunswick, NJ, USA). The venous blood was frozen for inspection. NCIS scale was used for the 90 patients in a retrospective manner. VIDAS BRAHMS PCT kit by bioMérieux (Marcy l'Etoile, France) was used for PCT. Enzyme-linked fluorescence assay (ELFA) technology was applied with the reference value of <0.5 ng/ml for newborns between 3 and 28 days. Boditech Med Inc. (Chuncheon, Korea) high-sensitivity C-Reactive Protein detection kit was used for high-sensitivity CRP. Immunofluorescence was applied with newborn reference value of ≤2 mg/l. Moreover, blood routine examination of the patients was carried out. Special Protein Analyzer manufactured by SEAC (Florence, Italy) was used for CRP inspection. Immune scatter turbidimetry method was used with a normal value of 0–0.8 mg/dl. The study started from the time when the patient was admitted into the Emergency ICU and ended at the time when the patient was discharged from the hospital or succumbed to the disease. Comparison was made on the difference of the BLA level, CRP and PRISM scores of the two groups.
+ Open protocol
+ Expand
5

Serum CRP and PCT Quantification Protocols

Check if the same lab product or an alternative is used in the 5 most similar protocols
To compare gene expression classifier results to known biomarkers, we performed serum CRP and PCT testing. Quantitative measurement of human CRP by sandwich immunoassay with electrochemiluminescent detection was performed using 2 different platforms depending on the availability and country of location of serum samples. Some serum CRP measurements were performed at 1:1000 dilution, in duplicate, using Human CRP V-PLEX assay kit and QuickPlex SQ 120 Imager (Meso Scale Discovery, Rockville, MD; performed through the Duke Molecular Physiology Institute Biomarkers Core). Other serum CRP measurements were performed using the CRP XL assay kit (DiAgam, Ghislenghien, Belgium; performed through Durdans Laboratory, Sri Lanka).
Quantitative measurement of human PCT was also performed using 2 different platforms depending on the availability and location of serum samples. Some serum PCT measurements were conducted using the VIDAS BRAHMS PCT kit using the ELISA technique via the Mini-VIDAS platform (bioMérieux, Marcy-l’Étoile, France). Other serum PCT measurements were performed using the Exdia PCT (Precision Biosensor Inc., Daejeon, Korea; performed through Durdans Laboratory, Sri Lanka).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!