The largest database of trusted experimental protocols

6520 q tof lc ms mass spectrometer

Manufactured by Agilent Technologies

The 6520 Q-TOF LC/MS mass spectrometer is a high-resolution mass spectrometry instrument designed for accurate mass measurements and identification of unknown compounds. It combines a quadrupole mass filter with a time-of-flight (TOF) mass analyzer to provide high-speed, high-sensitivity, and high-resolution mass analysis.

Automatically generated - may contain errors

2 protocols using 6520 q tof lc ms mass spectrometer

1

Comprehensive Characterization of Nanomaterials

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 1H-nuclear magnetic resonance (1H-NMR) spectra were recorded in DMSO-d6 on a Bruker Spectrospin Avance 400 MHz NMR spectrophotometer. Chemical shifts are given in ppm downfield from tetramethylsilane. Infrared (IR) spectra were measured on a Perkin Elmer Spectrum One spectrophotometer. UV-vis absorption spectra were recorded on a Cary 60 UV-vis spectrophotometer (Agilent Technologies). High resolution mass spectrometry (HRMS) was carried out using an Agilent 6520 Q-TOF LC/MS mass spectrometer. Elemental analysis was performed on a Perkin-Elmer 240 elemental analyzer. Fluorescence spectra and resonance light scattering (RLS) spectra were measured at room temperature using a SHIMADZU RF-5301PC spectrofluorimeter. The transmission electron micrograph (TEM) images were recorded on a German Leica TCS-SP8 transmission electron microscope. A Malvern Zetasizer Nano ZS90 particle size analyzer was used for dynamic light scattering (DLS) studies.
+ Open protocol
+ Expand
2

Phytochemical and Biological Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
IR spectra were recorded on an Avater-360 FT-IR spectrophotometer with KBr pellets. UV spectra were run on a Carry-50 UV-VIS spectrophotometer.
HRESIMS were measured by an Agilent 6520 Q-TOF LC-MS mass spectrometer. 1D-and 2D-NMR spectra were recorded on a Bruker AV-400 spectrometer (400 MHz for 1 H and 100MHz for 13 C, respectively).
Semi-preparative HPLC was performed on a Hitachi Spectra Series HPLC system equipped with an L-2130 pump and a UV L-2400 detector in a YMC-ODS column (10 mm × 250 mm, 5 μm); flow rate at 1.5 mL/min; wavelength detection at 254 nm. Fractions were monitored by TLC, and spots were visualized by heating silica gel plates after spraying with 10% H 2 SO 4 in EtOH. GC analysis was carried out on an Agilent 7820A GC system using an HP-5 (30 m × 0.32 mm × 0.25 μm) column; detection FID; carrier gas N 2 ; injection temperature 250℃, detection temperature 250℃, column temperature 180℃. Preparative HPLC methanol and chemicals of analytical grade, such as methanol, dichloromethane, and ethyl acetate, were purchased from Sinopharm Chemical Reagent Co., Ltd. The cell line, RAW264.7 (mouse macrophage), was available and maintained in our laboratory.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!