The largest database of trusted experimental protocols

Astra 5 software vs 5

Manufactured by Wyatt Technology

The Astra V software is a data analysis and visualization tool designed for use with Wyatt Technology's light scattering and SEC/GPC instruments. It provides features for data processing, analysis, and presentation. The 5.3.4.20 version is a specific release of the Astra V software, which may include bug fixes, performance improvements, or new functionalities compared to earlier versions.

Automatically generated - may contain errors

2 protocols using astra 5 software vs 5

1

Aggregation Analysis of Labeled and Unlabeled Proteins

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analysis of the aggregation status of labeled and not labeled γ-C and KTI (2 mg/mL) was performed by using the serial system composed by a HPLC pump (515 HPLC pump, Waters), a SEC column (Superose 12, 10/300, GE Healthcare, Milan, Italy), a UV spectrophotometer (Dual λ absorbance detector 2487, Waters), a multi-angle light scattering device (DAWN HELEOS, Wyatt, Santa Barbara, CA, USA), provided with a fast photon counter (QELS), and a differential refractometer (Waters), as previously described in Caparo et al. [21 (link)]. Two hundred µL of samples, previously centrifuged to remove the insoluble fraction, were injected with PBS (pH 7.5) as mobile phase, at a flow rate of 0.5 mL/min. Molar masses were calculated by means of the Astra V software vs. 5.3.4.20 (Wyatt), using a dn/dc value of 0.185 for γ-C samples.
+ Open protocol
+ Expand
2

Size-Exclusion Chromatography and MALS Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Size-Exclusion Chromatography (SEC) combined with Multi-Angle Light Scattering (MALS) detection was performed in an HPLC system composed by a Waters 515 HPLC Pump, a Waters 2487 Dual λ Absorbance detector (Waters, Sesto San Giovanni, Italy), a Wyatt Dawn Heleos MALS and a Wyatt Optila T-rEX differential refractive index detector (Wyatt Technology, Santa Barbara, CA, USA).
200 μL of 2 mg/mL GCAP1 samples were run on a Superdex 75 Increase 10/300 GL column (GE Healthcare, Milan, Italy), by using 20 mM Tris-HCl, pH 8, 5 mM 2-mercaptoethanol, with/without 1 mM CaCl2, as mobile phase, at a flow rate of 0.8 mL/min. Molar masses were calculated by means of the Astra V software vs. 5.3.4.20 (Wyatt), using a dn/dc value of 0.185.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!