The largest database of trusted experimental protocols

Wallac wizard 1480 wizard

Manufactured by PerkinElmer

The Wallac Wizard 1480 Wizard is a multi-mode microplate reader capable of performing various detection methods such as absorbance, fluorescence, and luminescence. It is designed to handle a wide range of sample types and assays across diverse applications.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using wallac wizard 1480 wizard

1

Biodistribution of Radiolabeled rA1M

Check if the same lab product or an alternative is used in the 5 most similar protocols
For the biodistribution study, eight mice were injected i.v. with 125I-labelled rA1M (5 mg/kg) and eight mice were injected i.v. with 125I-labelled A1M (5 mg/kg) and the positively charged amino acid solution, Vamin (Vamin 18N/l, Fresenius Kabi, Sweden, 35 mg/200 µL, administered i.p.). Four mice of each group were sacrificed after 10 min and the other four after 60 min. Kidneys, livers, spleens, and femurs were collected in scintillation tubes, weighed, and measured in a Nal (TI) well counter (Wallac Wizard 1480 Wizard, PerkinElmer). Results were corrected for background and radioactive decay. Organ specific uptake values were calculated as percent injected activity per gram of tissue (%IA/g).
+ Open protocol
+ Expand
2

Biodistribution of 111In-DTPA-11B6 in Prostate Cancer

Check if the same lab product or an alternative is used in the 5 most similar protocols
Biodistribution studies were conducted to evaluate the uptake of 111In-DTPA-11B6 in human prostate cancer LNCaP xenografts. Mice (n = 3 to 5 per time point) received 111In-DTPA-11B6 (0.4 to 0.6 MBq, 20 μg of mAb, in approximately 100 μL of PBS) through intravenous (i.v.) tail vein injection. Blood and organs (including tumour) were taken at 4, 24, 48, 72 and 168 h post-injection, weighed and measured in a NaI(TI) well counter (Wallac Wizard 1480 Wizard, Perkin Elmer). The activity injected into each animal was measured and used to determine the count rate, in comparison with a standard solution of 111In-DTPA-11B6. Data were corrected for background and physical decay.
Organ-specific uptake values were calculated as percent injected activity per gram of tissue (%IA/g) or percent injected activity (%IA). Among the organs resected were the lateral and ventral prostate, from now on referred to as prostate, and the submandibular glands, from now on called salivary glands.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!