9 protocols using acephate

1

Analytical Technique for Soil Contaminants

Check if the same lab product or an alternative is used in the 5 most similar protocols
The used substrate papers, glass fiber film (SB08, CB06, BT53, RB45), polyester fiber film (VL78), and special absorbent paper (SX18) were purchased from Shanghai Jinbiao Biological Technology Co., Ltd. (Shanghai, China), cadmium oxide, selenium powder, liquid paraffin, oleic acid, oleyl-amine, tetra-methoxy-silane(TMOS), tetra-ethoxy-silane (TEOS), tetra-propoxy-silane (TPOS), 3-aminopropyltriethoxylsilane (APTES), trimethoxy-silyl-propane-thiol (MPTMS), and vinyl-trimethoxy-silane(VMS) were supplied by Aladdin (Shanghai, China); urea, sodium dodecyl sulfonate (SDS), sodium chloride, trichlorfon, acephate, fenthion and dimethoate were supplied by Sigma-Aldrich (Shanghai, China). Soybean samples were purchased from a local market in Xi’an (Shaanxi, China). All the water used in the experiment was ultrapure. All reagents used were of at least analytical grade.
+ Open protocol
+ Expand
2

Quantitative Analysis of Pesticide Residues

Check if the same lab product or an alternative is used in the 5 most similar protocols
The certified reference materials of acephate, chlorpyrifos, dimethoate, emamectin benzoate, imidacloprid, monocrotophos, phenthoate, phorate, profenofos, quinalphos, and triphenyl phosphate (TPP, internal standard) were procured from Sigma-Aldrich Chem. Pvt. Ltd., India, based on the information collected on the types of pesticides used by the farmworkers. The analytical-grade formic acid was procured from Fluka Pvt. Ltd., India, and the other organic solvents, acetonitrile and methanol (pestanal-grade), were obtained from Sigma Aldrich, Merck KGaA Darmstadt, Germany. Salts such as sodium chloride (anhydrous) and sodium sulfate and the analytical-grade reagent ethanol were obtained from Merck, India, and the HPLC column was procured from Agilent Technologies Pvt. Ltd., India. Water was purified with a Millipore Direct Q purification system (Lab Link, Germany).
+ Open protocol
+ Expand
3

Multianalyte Pesticide Detection in Rice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sodium citrate tribasic dihydrate (HOC(COONa) (CH2COONa)2·aq), gold (III) chloride trihydrate (HAuCl4·3H2O, 99.9%), acephate (O,S-Dimethyl N-acetylphosphoramidothioate), carbendazim (Methyl benzimidazol-2-ylcarbamate), thiamethoxam (3-(2-Chloro-5-thiazolylmethyl)tetrahydro-5-methyl-N-nitro-4H-1,3,5-oxadiazin-4-imin), tricyclazole (8-methyl-[1,2,4]triazolo[3,4-b][1,3]benzothiazole), rhodamine 6G (R6G), hydrochloric acid 37% (HCl), acetic acid ≥99% (HAc), acetonitrile ≥99.9% (MeCN), absolute ethanol ≥99.8%, magnesium sulphate (MgSO4), sodium chloride (NaCl), sodium acetate (NaOAc), potassium chloride (KCl), 96-well flat bottom ELISA plates and polyester foam tipped sterile swabs were all purchased from Sigma Aldrich (UK). Indian basmati rice samples were produced and supplied by Green Saffron (Cork, Ireland).
+ Open protocol
+ Expand
4

Analytical Standards for Pesticide Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analytical grade standards of acephate, acetamiprid, carbendazim chlorpyrifos, cypermethrin, imidacloprid, tebuconazole and thiamethoxam were procured from Sigma Aldrich, India and profenofos was provided as CRM (Certified Reference Material) by IARI, New Delhi. The formulations of the above-mentioned pesticides were procured from the local market.
+ Open protocol
+ Expand
5

Acephate Toxicity in Pregnant Rats

Check if the same lab product or an alternative is used in the 5 most similar protocols
This study’s experimental protocols were approved by the Ethical Committee for the Care and Use of Laboratory Animals at the University of Gafsa (Reference Number: FSG-AE-20-23). Overall, 24 virgin female Wistar albino rats obtained from SIPHAT (Tunisia) (age, 60 days; weight, 210–240 g) were individually housed in a temperature (21 °C) and humidity-controlled room, with an artificially reversed light–dark cycle and access to water and food. These rats were weighed and randomly divided into three treatment groups. The rats in group 1 (n = 8) were considered as controls and those in groups 2 and 3 (n = 8 rats per group) were administered acephate (purity 98%; Sigma-Aldrich, St. Louis, MO, USA) by gavage from day 6 of gestation, which corresponded to the date of fetal implantation, until delivery. Furthermore, considering the published lethal oral dosage of 50% (LD50) acephate (866 mg/kg) [10 (link)] and previous findings about its toxic effects on different biological systems, groups 2 and 3 were administered 14 or 28 mg/kg body weight acephate based on oral LD50 values of 1/60 and 1/30, respectively.
+ Open protocol
+ Expand
6

Neurotoxic Pollutants Screening in Zebrafish

Check if the same lab product or an alternative is used in the 5 most similar protocols
Thirty neurotoxic pollutants, from 5 chemical groups (herbicide, insecticide, metal elements, non-metal elements, and toxins) were selected (Table 1). The following compounds were purchased from Sigma-Aldrich (St. Louis, MO, USA): acephate, acetamiprid, aldicarb, cadmium(II) sulfate (Cd), carbaryl, carbofuran, chlorpyriphos, clothianidin, diazinon, dichlorvos, endosulfan, esfenvalerate, fenitrothion, malathion, manganese(II) chloride (Mn), mercury(II) chloride (Hg), lead(II) nitrate (Pb), permethrin, selenium dioxide (Se), sodium fluoride (fluorine), thiamethoxam and β-cyfluthrin. Atrazine and deltamethrin were purchased from Riedel-de Haën (Germany). Dinotefuran and fenvalerate were purchased from Supelco™ Analytical (USA). Glyphosate was purchased from Santa Cruz Biotechnology (USA), whereas domoic acid, okadaic acid and saxitoxin were purchased from Cifga lab SA (Spain). CAS numbers of each chemical are provided in Table 1. Stock solutions of each compound were prepared on the day of the experiment. Solutions were either prepared directly in fish water or in dimethyl sulfoxide (DMSO), according to compound solubility.
Experimental solutions were prepared in fish water from the stock solutions.
DMSO was added to all conditions, including control, to a final concentration of 0.1%, which has been previously found not to affect larvae behavior (Faria et al., 2019c) .
+ Open protocol
+ Expand
7

Pesticide Analytical Standards Procurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
The standard of chlorpyrifos, acephate, diazinon, dimethoate, quinalphos, malathion and fenitrothion were obtained from Sigma-Aldrich (St Louis, MO, USA) via Bangladesh Scientific Pvt. ltd. Dhaka, Bangladesh. Standards of all pesticides contained >99.6% purity. Methanol, acetone, gradient grade acetonitrile, sodium chloride (NaCl), anhydrous magnesium sulphate (MgSO 4 ) and Primary Secondary Amine (PSA) were purchased from Bangladesh Scientific Pvt. ltd. Dhaka, Bangladesh.
+ Open protocol
+ Expand
8

Pesticide Extraction and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The standard (>99.6% pure) of acephate, chlorpyrifos, diazinon, dimethoate, fenitrothion, malathion and quinalphos were purchased from Sigma-Aldrich (St Louis, MO, USA) via Bangladesh Scientific Pvt. Ltd. Dhaka, Bangladesh. Analytical grade methanol, acetone, HPLC grade acetonitrile, sodium chloride (NaCl), anhydrous magnesium sulphate (MgSO 4 ) and Primary Secondary Amine (PSA) were purchased from Bangladesh Scientific Pvt. Ltd.
+ Open protocol
+ Expand
9

Pesticide Extraction and Identification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The standard (>99.6% pure) of acephate, chlorpyrifos, diazinon, dimethoate, fenitrothion, malathion, and quinalphos were purchased from Sigma-Aldrich (St Louis, MO, USA) via Bangladesh Scientific Pvt. Ltd. Dhaka, Bangladesh. Analytical grade methanol, acetone, HPLC grade acetonitrile, sodium chloride (NaCl), anhydrous magnesium sulfate (MgSO 4 ), and Primary Secary Amine (PSA) were purchased from Bangladesh Scientific Pvt. Ltd.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!