The largest database of trusted experimental protocols

Inlab cool

Manufactured by Mettler Toledo
Sourced in Switzerland

The InLab Cool is a pH/ORP electrode from Mettler Toledo. It is designed for temperature-sensitive measurements in laboratory environments.

Automatically generated - may contain errors

5 protocols using inlab cool

1

Monitoring pH Shifts During Freezing

Check if the same lab product or an alternative is used in the 5 most similar protocols
To monitor pH shifts in the intermediate bulk during freezing, a preliminary examination was done using a simplified medium. All substances without significant contribution to the pH were omitted leaving only phosphate and Tris/HCl. To show the dependency between pH-stability and buffer concentration, 3 different concentrations of Tris/HCl, namely 0.1 M, 0.5 M and 1.0 M, were analysed. We prepared the respective Tris solutions, before phosphoric acid was added to obtain a phosphate concentration of 1.57 × 10–2 mol/l (see also Table 1) and then pH was adjusted to 7.0 by addition of HCl. These solutions were frozen as described above with the exception of a lower freezing temperature of −25 °C which was chosen for a more gentle treatment of the measuring system. The pH was monitored during the whole freezing process using a low temperature pH-electrode (InLab Cool, Mettler Toledo) with an added thermocouple for correction of temperature dependent characteristics of the measuring system. The pH electrode was placed in the centre of the freezing container. All measurements were done in duplicates.
+ Open protocol
+ Expand
2

Measuring pH of Food Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH value of filtrates was measured by mixing 10 g of a minced sample with 50 mL of deionised water for 1 min using a homogeniser (Bamix 200, Greifensee, Switzerland). The pH was measured using a digital pH meter (Seven Compact S220, Mettler Toledo, Greifensee, Switzerland) equipped with a pH electrode (Seven Compact S220, InLab Cool, Mettler Toledo, Greifensee, Switzerland). The pH readings were recorded exactly 4 min after the insertion of the electrode into the sample. The pH meter was standardised with buffer solutions at pH 2.0, 4.0, 7.0, and 10.0.
+ Open protocol
+ Expand
3

Determination of pH and Redox Potential

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ten grams of MSPM batters was homogenized with 50 mL distilled water to determine the pH and oxidative reduction potential (ORP) using an 600-W blender (MSM 66120; BSH Hausgeräte GmbH, Munich, Germany) for 1 min at a speed equal to 14,000 rpm. Then, the digital pH-meter (Mettler Delta 350; Mettler Toledo, Schwerzenbach, Switzerland) was used to measure the pH value with an automatic compensation temperature, a glass-calomel electrode In Lab Cool (Mettler Toledo, Greifensee, Switzerland), and ORP value with an electrode In Lab Redox Pro (Mettler Toledo, Greifensee, Switzerland). The obtained result ORP value (mV) was calculated into the redox potential value in relation to the standard hydrogen electrode EH (mv). To this end, the potential value of the reference electrode at a temperature of 20°C (207 mV) was added to the readout value obtained with the equipment.
+ Open protocol
+ Expand
4

Determination of Meat Product pH

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH value of the meat products was determined according to PN-ISO 2917:2001. A test sample of 10 g weight was mixed with 50 cm 3 of distilled water and homogenized using an 800 W blender (Bosch, Munich, Germany) for 1 minute at a speed equal to 14,000 RPM. Measurement of the pH of the homogenates was performed using a Delta 350 pH meter (Mettler Toledo, Schwerzenbach, Switzerland) with an automatic compensation temperature, using a glass-calomel electrode In Lab Cool (Mettler Toledo, Greifensee, Switzerland).
+ Open protocol
+ Expand
5

pH Measurement of Minced Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
The pH value was measured in a filtrate by mixing 10 g of a minced sample with 50 mL of de-ionized water for 1 min, using a homogenizer (Bamix 200, Greifensee, Schweiz). The pH was measured with a digital pH meter (Mettler-Toledo, Seven Compact S220, Greifensee, Schweiz) equipped with a pH electrode (InLab Cool, Mettler-Toledo, Seven Compact S220, Greifensee, Schweiz). The pH readings were recorded at exactly 4 min after the insertion of the electrode into the sample. The pH meter was standardized with buffer solutions at pH 2.0, 4.0, 7.0, and 10.0.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.