6540 agilent ultra high definition accurate mass q tof ms

Manufactured by Agilent Technologies
Sourced in United States

The 6540 Agilent Ultra-High-Definition Accurate-Mass q-TOF-MS is a quadrupole time-of-flight mass spectrometer designed for high-resolution, accurate-mass analysis. It provides precise mass measurements and detailed structural information for a wide range of analytes.

Automatically generated - may contain errors

3 protocols using 6540 agilent ultra high definition accurate mass q tof ms

1

HPLC-MS Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
An Agilent 1200-LC system (Agilent Technologies, Palo Alto, CA, USA) equipped with a vacuum degasser, autosampler, and binary pump was used for the chromatographic determination. The column used consisted of a Gemini® NX-C18 (3 µM, 150 × 2 mm ID) (Phenomenex). The mobile phases were made of water (A) and acetonitrile (B), both with 0.1% of formic acid. The gradient program was as follows: 0–6 min, 50% B; 7–12 min, 100% B; 13–20 min, 50% B. The injection volume was set at 5 µL and the flow rate at 0.2 mL/min. Mass spectrometry (MS) analysis was performed employing a 6540 Agilent Ultra-High-Definition Accurate-Mass q-TOF-MS coupled to the HPLC, equipped with an Agilent Dual Jet Stream electrospray ionization (Dual AJS ESI) interface in positive and negative ionization modes under the following conditions: interface in positive and negative ionization modes; drying gas flow (N2) 12.0 L min−1; nebulizer pressure, 50 psi; gas drying temperature, 370 °C; capillary voltage, 3500 V; fragmentor voltage, 160 V. Analysis was carried out in MS mode and MS spectra were collected within the scan range of 50–1500 m/z. Integration and data acquisition were performed employing the Mass Hunter Workstation software.
+ Open protocol
+ Expand
2

HPLC-DAD-q-TOF-MS Analysis of Polyphenols

Check if the same lab product or an alternative is used in the 5 most similar protocols
Power extracts from the extraction of 0.5 g of samples were redissolved in 3 mL of methanol/water (80:20 v/v). After their filtration, extracts were analyzed by HPLC-DAD-q-TOF-MS (Agilent 1200 series coupled to 6540 Agilent Ultra-High-Definition Accurate-Mass q-TOF-MS, Agilent Technologies, Palo Alto, CA, USA) according to the method proposed by Gómez-Caravaca et al. [13 (link)].
Identification was performed based on relative retention times, UV-Vis spectra, and mass spectra obtained by q-TOF-MS and from the literature. Quantification was carried out using calibration standards curves of gallic acid, coumaric acid, ferulic acid, vanillic acid, catechin, quercetin, ellagic acid, and mangiferin (Sigma Aldrich, St. Louis, MO, USA). Spectral and chromatographic data are compliled in Supplementary Table S1. Integration and data processing were performed using Mass Hunter Workstation Software, Qualitative Analysis, version B.07.00 (Agilent Technologies, Inc. 2014).
+ Open protocol
+ Expand
3

Degradation Product Identification by LC-QTOF-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
For the identification of degradation products, an Agilent 1200-LC system (Agilent Technologies, Palo Alto, CA, USA), for the chromatographic determination, coupled to a 6540 Agilent Ultra-High-Definition Accurate-Mass q-TOF-MS, equipped with an Agilent Dual Jet Stream electrospray ionization (Dual AJS ESI) for mass spectrometry analysis, was employed. Chromatographic separation was developed in a Gemini-NX column C18 (Phenomenex, 150 mm × 4.6 mm, 5 µm particle size). The mobile phases consisted of water (A) and acetonitrile (B), both with 0.1% of formic acid. The gradient was as follows: 0-6 min, 50% B; 7-12 min, 100% B; 13-20 min, 50% B. The injection volume was 5 µL and the flow rate 0.2 mL/min. The following conditions were employed for mass spectrometry: interface in positive ionization mode; drying gas flow (N 2 ), 12.0 L min -1 ; nebulizer pressure, 50 psi; gas drying temperature, 370 • C; capillary voltage, 3500 V; fragmentor voltage, 160 V. Analyses were carried out in MS mode, and MS spectra were collected within the scan range 50-1500 m/z.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!