The largest database of trusted experimental protocols

Sta apixaban calibrator

Manufactured by Diagnostica Stago
Sourced in France

The STA-Apixaban calibrator is a laboratory diagnostic tool used to calibrate and validate the measurement of apixaban, a direct oral anticoagulant, in patient samples. It provides a standardized reference material to ensure accurate and reproducible results when testing for apixaban levels.

Automatically generated - may contain errors

2 protocols using sta apixaban calibrator

1

Quantification of Anticoagulant and Antiseizure Drugs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Apixaban and rivaroxaban concentrations were measured in plasma by anti-Xa assay with Berichrom Heparin on the CS-2500 coagulation analyser calibrated with the STA-Apixaban calibrator or STA-Rivaroxaban calibrator (Diagnostica Stago, France). Dabigatran concentration was assessed by an in-house method for determination of diluted thrombin time18 (link). Levetiracetam concentration was determined by HPLCMS/MS (LCQ Fleet, Thermo Scientific, USA). Creatinine was measured in serum by a routine biochemical method and creatinine clearance was calculated using the Cockcroft-Gault formula.
+ Open protocol
+ Expand
2

Apixaban Anti-Xa Activity Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The anti-Xa activity of apixaban was measured in citrate-anticoagulated PPP by the Comparative Coagulation Laboratory in the Animal Health Diagnostic Center at Cornell University. The PPP was harvested from the supernatant of PRP after high-speed centrifugation (13,000 × g, Accuspin Micro, Thermo Scientific, Rockford, IL, USA) for 5 min. The PPP was frozen at −20°C and assays were performed in batches. The PPP was thawed at 37°C in a water bath before analysis with an automated coagulation analyzer (STA® Compact, Diagnostica Stago, Parsipanny, NJ, USA). The assay is configured with a bovine activated Factor X reagent added in excess to the test plasma and a chromogenic substrate of Factor Xa (STA®-Liquid anti-Xa, Diagnostica Stago). In this assay, residual, uninhibited Factor Xa cleaves the chromogenic substrate such that the inverse of the color change in the reaction mixture is proportional to the drug concentration in the test plasma. Results are expressed as ng/mL anti-Xa activity, based on the calibration standard containing known apixaban concentrations in human plasma (STA®-Apixaban Calibrator, Diagnostica Stago). Assay controls, consisting of apixaban spiked-human plasma (STA®-Apixaban Controls) were measured before each batch of test samples.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!