The largest database of trusted experimental protocols

Blood collection tubes

Manufactured by Medtronic

Blood collection tubes are designed to safely and effectively collect blood samples for laboratory analysis. They are made of high-quality materials and are available in various sizes and configurations to accommodate different clinical needs.

Automatically generated - may contain errors

2 protocols using blood collection tubes

1

Plasma Cytokine Quantification via CBA

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were harvested via cardiac puncture and collected in blood collection tubes (Covidien). The plasma fractions were prepared by centrifugation of the harvested blood at 3000 × g for 5 min at 4 °C. The concentrations of cytokines in plasma were determined using the CBA Mouse Inflammation Kit (BD Biosciences) as described above.
+ Open protocol
+ Expand
2

Plasma Lipid Metabolite Extraction and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
After animal sacrifice, the blood was harvested by cardiac puncture with a disposable syringe, immediately transferred to blood collection tubes (Covidien, Mansfield, MA), and centrifuged (1,500 g, 10 min, 4 °C) to yield plasma. The plasma was stored at −80 °C until analysis. To extract lipid metabolites from plasma, deuterated internal standards (d11-14,15-DHET, d11-11,12-EET, d4-9-HODE, d8-5-HETE, d4-6-keto PGF1a, d4-LTB4, d4-PGE2, d4-TXB2, 500 nM) were added into ~200 μL plasma. The mixture was then loaded onto pre-washed Waters® Oasis solid phase extraction (SPE) cartridges, and washed with 5% methanol containing 0.1% acetic acid, and the analytes were eluted with methanol and ethyl acetate, dried by a centrifugal vacuum evaporator, and then dispersed in methanol for LC-MS/MS analysis. The LC-MS/MS analysis was performed on an Agilent 1200SL HPLC coupled with a 4000 QTRAP MS/MS (AB Sciex) as previously14 (link). The peaks were identified based on retention time and specific multiple reaction monitoring (MRM) transitions of the standards of lipid metabolite. The concentrations of the lipid metabolites were calculated according to calibration curves of standards.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!