The largest database of trusted experimental protocols

Msp96 target ground steel bc

Manufactured by Bruker
Sourced in Germany

The MSP96 target ground steel BC is a laboratory equipment product designed for use in mass spectrometry applications. It serves as a sample support platform for the analysis of various biomolecules and other materials. The core function of this product is to provide a standardized and reproducible surface for sample preparation and analysis.

Automatically generated - may contain errors

9 protocols using msp96 target ground steel bc

1

MALDI-TOF Mass Spectrometry Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was performed on a Bruker microflex benchtop MALDI-TOF MS (Bruker Daltonics, Bremen, Germany) using reflector acquisition mode, positive ion source, and 800 shots per spot. α-Cyano-4-hydroxy-cinnamic acid (HCCA) was chosen as matrix and dried-droplet method for sample preparation on a micro scout target (MSP96 target ground steel BC, Bruker Daltonics). The recorded data was analyzed by Flex Analysis 2.4 software.
+ Open protocol
+ Expand
2

MALDI-TOF MS Peptide Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Matrix-assisted laser
desorption/ionization
time-of-flight mass spectrometry was performed on a Bruker microflex
benchtop MALDI-TOF MS (Bruker Daltonics, Bremen, Germany). Samples
were prepared on a micro scout target (MSP96 target ground steel BC,
Bruker Daltonics) via dried-droplet method using α-cyano-4-hydroxy-cinnamic
acid (HCCA, Sigma-Aldrich, Handels GmbH, Vienna, Austria) as matrix.
All spectra were recorded by summarizing 800 laser shots per spot
and Flex Analysis 2.4 software was used for data processing.
+ Open protocol
+ Expand
3

MALDI-TOF Mass Spectrometry Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mass spectrometry was conducted on a Bruker microflexTM bench-top MALDI-TOF MS (Bruker Daltonics, Bremen, Germany) with a 20 Hz laser source. Sample preparation was performed according to dried-droplet method on a micro scout target (MSP96 target ground steel BC, Bruker Daltonics) using α-cyano-4-hydroxycinnamic acid (HCCA, Sigma-Aldrich, Handels GmbH, Vienna, Austria) as matrix. Flex Analysis 2.4 software was used for processing of the recorded data.
+ Open protocol
+ Expand
4

MALDI-TOF Mass Spectrometry of Skimmed Milk

Check if the same lab product or an alternative is used in the 5 most similar protocols
After thawing, skimmed milk fractions were centrifuged at 20,000 g for 20 min at + 4°C to remove cell debris and bacteria. Then, each sample was diluted 1:100 with ultrapure water (20 (link)) and mixed (1:1) with a matrix solution composed of sinapinic acid (Bruker Daltonics, Bremen, Germany) saturated in 50% v/v acetonitrile containing 0.1% trifluoroacetic acid (Merck Darmstadt, Germany). An aliquot (0.5 μl) of each sample was spotted in triplicate on an MSP 96 target ground steel BC (Bruker Daltonics), previously overlaid with a thin layer of sinapinic acid saturated in 100% ethanol (Merck), and allowed to dry for 10 min at room temperature. Spectral profiles were acquired using a MALDI-TOF Microflex LRF mass spectrometer (Bruker Daltonics) equipped with the FlexControl (v. 3.4) software (Bruker Daltonics). Spectra were recorded in the positive linear ion mode within the mass range 4,000–20,000 m/z (laser frequency 20 Hz; ion source 1 voltage, 19.53 kV; ion source 2 voltage, 18.12 kV; lens voltage, 8.12 kV). Three independent spectra for each sample (500 shots each at random positions on the same target place, for spectrum) were manually collected, externally calibrated by the Protein Calibration Standard 1(Bruker Daltonics) and subsequently analyzed.
+ Open protocol
+ Expand
5

MALDI-TOF MS Sample Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was performed on a Bruker microflex benchtop MALDI-TOF MS (Bruker Daltonics, Bremen, Germany). Samples were prepared on a micro scout target (MSP96 target ground steel BC, Bruker Daltonics) via dried-droplet method using α-cyano-4-hydroxy-cinnamic acid (HCCA, Sigma-Aldrich, Handels GmbH, Vienna, Austria) as matrix. All spectra were recorded by summarizing 800 laser shots per spot and Flex Analysis 2.4 software was used for data processing.
+ Open protocol
+ Expand
6

MALDI-TOF Mass Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mass analysis was conducted on a Bruker microflex™ bench-top MALDI-TOF MS (Bruker Daltonics, Bremen, Germany) using dried-droplet method on a micro scout target (MSP96 target ground steel BC, Bruker Daltonics) with α-cyano-4-hydroxycinnamic acid (HCCA, Sigma-Aldrich, Handels GmbH, Vienna, Austria) as matrix. Flex Analysis 2.4 software (Bruker Daltonics, Bremen, Germany) was used for data processing.
+ Open protocol
+ Expand
7

MALDI-TOF Mass Spectrometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Matrix-assisted
laser desorption/ionization
time-of-flight mass spectrometry was performed on a Bruker microflex
benchtop MALDI-TOF MS (Bruker Daltonics, Bremen, Germany) using reflector
acquisition mode, positive ion source, and 800 shots per spot. α-Cyano-4-hydroxy-cinnamic
acid (HCCA) was chosen as matrix and dried-droplet method for sample
preparation on a micro scout target (MSP96 target ground steel BC,
Bruker Daltonics). The recorded data was analyzed by Flex Analysis
2.4 software.
+ Open protocol
+ Expand
8

Radiolysis Study of Lu-PSMA I&T

Check if the same lab product or an alternative is used in the 5 most similar protocols
100 µL of a 50 µg/mL solution of natLu-PSMA I&T in a 1 mL Eppendorf tube was subjected to external irradiation using a 137Cs IBL 437L irradiator (CIS US Inc., NY, USA) at a dose rate of about 5 Gy/min for 100 min reaching a dose of 500 Gy. The sample was purified by HPLC (injection volume 50 µL) using HPLC method A and the peaks of the impurity and the main peak due to natLu-PSMA I&T were collected and analysed by MALDI-TOF MS.
Mass analysis was conducted on a Bruker microflex® bench-top MALDI-TOF MS (Bruker Daltonics, Bremen, Germany) using dried-droplet method on a micro scout target (MSP96 target ground steel BC, Bruker Daltonics) with α-cyano-4-hydroxycinnamic acid (HCCA, Sigma-Aldrich, Handels GmbH, Vienna, Austria) as matrix. Flex Analysis 2.4 software (Bruker Daltonics, Bremen, Germany) was used for data processing.
+ Open protocol
+ Expand
9

MALDI-TOF Mass Spectrometry Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mass spectrometry was conducted on a Bruker microflex bench-top MALDI-TOF MS (Bruker Daltonics, Bremen, Germany). Samples were prepared via dried-droplet on a micro scout target (MSP96 target ground steel BC, Bruker Daltonics) using α-cyano-4-hydroxy-cinnamic acid (HCCA, Sigma-Aldrich, Handels GmbH, Vienna, Austria) as matrix. Recorded data, summation of 800 shots per spot, was processed using Flex Analysis 2.4 software.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!