The largest database of trusted experimental protocols

Ab269555

Manufactured by Abcam

Ab269555 is a lab equipment product offered by Abcam. It is a device designed for use in scientific research applications. The core function of this product is to perform a specific task or activity within a laboratory setting. No further details about the intended use or features of this product can be provided in an unbiased and factual manner.

Automatically generated - may contain errors

3 protocols using ab269555

1

Quantifying Alzheimer's Biomarkers and Gal-3 in Human Brains

Check if the same lab product or an alternative is used in the 5 most similar protocols
Meso Scale Discovery (MSD) kits were used to measure the levels of Aβ42, p-Tau, and t-tau in the RIPA fraction of the human brain. Serial dilutions of the RIPA fractions were tested to measure protein levels accurately. Before performing the assay, protein levels were measured using a Thermofisher BCA Assay Kit. With those results, 1 μg of protein from the soluble fraction was diluted to evaluate Aβ42, t-tau and p-Tau levels. The plates were developed and read using a QuickPlex Q120 reader (Meso Scale Diagnostics). ELISA plates from Abcam (ab269555) were used to measure the levels of Gal-3 (detection range 58.8–2000 pg/ml) in tissue homogenates. The protocol was carried out according to the manufacturer’s instructions. A Biotek Synergy 2 was used to read the ELISA Gal-3 assay.
+ Open protocol
+ Expand
2

ELISA for Galectin-3 Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Enzyme‐linked immunosorbent assay (ELISA) plates from Abcam (ab269555) were used to measure the levels of Gal‐3 (detection range 58.8 to 2000 pg/mL) in tissue homogenates, CSF, and serum samples. The protocol was carried out according to the manufacturer's instructions. A Biotek Synergy 2 was used to read the ELISA Gal‐3 assay. All samples were run in duplicate once. Mean inter‐assay Coeficients of Variances (CV) was 6.23. Samples were distributed in the plates according to the clinical group in similar proportions to avoid a bias caused by the plate. The ELISA and the analysis of the raw data were performed by different persons. CSF samples were not diluted. Tissue homogenates were diluted 1:100. Serum samples were diluted 1:20 or 1:50; the correction factor on diluted samples was applied when needed for the comparison. Our kit has been used previously to measure Gal‐3 levels in brain, CSF, and serum samples
24 (link),
34 (link), ,
+ Open protocol
+ Expand
3

Quantification of Secreted Galectins

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell suspensions were centrifuged at 300× g for 5 min and the supernatants (8–10 mL) were collected and frozen at −80 °C to use later for analyses of extracellular proteins. Concentrations of secreted galectin-1, galectin-3, and galectin-9 were measured using ELISA kits from Abcam (ab260053, ab269555, and ab213786) as described by the manufacturer. For all three kits, cell culture supernatant samples were diluted 4-fold in the supplied sample diluent that was found to fall within the range of concentrations that correspond to the standard curve. Absorbance at 450 nm was measured using a Model 3550 Microplate Reader (Bio-Rad).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists