The largest database of trusted experimental protocols

5 protocols using ethylene glycol dimethylacrylate

1

Synthesis and Characterization of Fluorescent Polymer Particles

Check if the same lab product or an alternative is used in the 5 most similar protocols
L-012 was purchased from Wako Chemicals USA, Inc. (Richmond, VA). 2-(2-Methoxyethoxy)ethyl methacrylate, methoxy PEG methacrylate (Mn 300), ethylene glycol dimethylacrylate, styrene, ammonium persulfate and sodium dodecyl sulfate and 1,1′,3,3,3′,3′-Hexamethylindotricarbocyanine (IR750) were purchased from Sigma-Aldrich (St Louis, MO). PMN neutralizing antibody (rabbit anti-mouse PMN) was bought from Accurate Chemical & Scientific Corp. (Westbury, NY, USA) PMN staining antibody (rat anti-mouse neutrophil antibody) was purchased from Abcam (Cambridge, MA, USA).
+ Open protocol
+ Expand
2

Synthesis and Characterization of Semiconductor Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cadmium chloride hemi(pentahydrate) (CdCl2·2.5H2O, >99%), zinc acetate dihydrate (Zn(OAc)2·2H2O, >99%), tellurium (Te, >99.8%), sodium borohydride (NaBH4, >96%), 3-mercaptopropionic acid (MPA, 99%), acrylamide (>98%), ethylene glycol dimethylacrylate (EGDMA, 98%), potassium persulfate (K2S2O8, >99%), dopamine hydrochloride (DA·HCl, 99%), adenosine 5′-diphosphate (ADP, >95%), l-arginine (Arg, >98%), l-histidine monohydrochloride monohydrate (His, >98%), l-lysine (Lys, >98%), l-serine (Ser, >99%), l-cysteine (Cys, 97%), l-tyrosine (Tyr, >98%), glycine (Gly, >98.5%), homovanillic acid (HVA, fluorimetric reagent), l-glutathione (GSH, >98%), bovine serum albumin (BSA, >96%), (d)-(+)-glucose (>99.5%), ascorbic acid (AA, >99%), l-aspartic acid (Asp, >98%), KCl (>99%), NaCl (>99%), CaCl2 (>96%), and MgCl2·6H2O (>99%) were purchased from Sigma-Aldrich (Saint-Quentin Fallavier, France) and were used without purification. All solutions were prepared with deionized water (18.2 MΩ cm). Phosphate-buffered saline (PBS) solution was prepared using [Na2HPO4·2H2O] = 0.2 M, [NaH2PO4·H2O] = 0.2 M and the final pH was adjusted to 7.4.
+ Open protocol
+ Expand
3

Synthesis and Application of Polymer-Based Dye Adsorbents

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methyl red (MR) and Congo red (CR) were purchased from Bendosen laboratory chemicals, Malaysia. Acrylic acid (AA), 2,2-azobisisobutyronitrile (AIBN) and ethylene glycol dimethyl acrylate (EGDMA) were obtained from Sigma-Aldrich, Germany. Toluene, acetic acid, acetone and methanol (MeOH) were received from R&M Chemicals, UK. All chemicals were used as received. The water samples used in the application process were retrieved from UNIMAS Soil Sciences Lab, UNIMAS water tank and from Samarahan River in Sarawak.
+ Open protocol
+ Expand
4

Synthesis of Magnetic Core-Shell Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were analytical grade (PA) and used without prior purification. Methyl methacrylate (MMA) 99%, vinyl pivalate (VPi) 99%, hexadecane 99%, benzoyl peroxide 75% and ethylene glycol dimethylacrylate (EGDMA) 98% were purchased from Sigma-Aldrich Brasil Ltda. (Rio de Janeiro, Brazil). Hydrochloric acid (HCl) 36.5–38% and oleic acid 99% were purchased from Synth (São Paulo, Brazil). Ferric chloride hexahydrate (FeCl3·6H2O) 97%, ferrous sulfate heptahydrate (FeSO4·7H2O) 99%, sodium hydroxide (NaOH) 99% and potassium persulfate (KPS) 99% were purchased from Vetec Química Fina Ltda. (Rio de Janeiro, Brazil) and 90% pure sodium dodecyl sulfate (SDS) was supplied by Reagen Produtos para Laboratórios Ltda. (Parana, Brazil). Nitrogen gas was supplied by White Martins Gases Industriais Ltda. (Rio de Janeiro, Brazil) with 99.5% purity. Scheme 1 illustrates the experimental protocol for the synthesis of poly(Methyl methacrylate)/Fe3O4/poly(vinyl pivalate) magnetic core–shell nanoparticles.
+ Open protocol
+ Expand
5

UV-Cured Poly(Ethyl Acrylate) Films

Check if the same lab product or an alternative is used in the 5 most similar protocols
Films of poly(ethyl acrylate) were obtained by UV polymerization. Briefly, ethyl acrylate (EA; 99%, Sigma-Aldrich) with 2 wt% of ethylene glycol dimethyl acrylate (EGDMA; 98% Sigma-Aldrich) as crosslinker and 1 wt% of benzoin (Scharlab) as initiator were stirred for 15 min at room temperature. Then, the solution was injected between two glass plates separated by a wire of 1.2 mm in diameter, and placed in an ultraviolet oven for 8 h to let the polymerization occur. Subsequent post-polymerization was carried out at 90ºC for 24 h. At that moment films were rinsed for 24 h in boiling ethanol, which was changed every 8 h, to remove residues. Finally, films were dried at room conditions for 24 h, 24 h more under vacuum and under vacuum at 60ºC for 24 extra hours before any ensuing experiment.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!