The largest database of trusted experimental protocols

Omnisec software v5

Manufactured by Malvern Panalytical
Sourced in France

The OmniSEC software (v5.12) is a comprehensive data analysis tool designed for gel permeation chromatography (GPC) and size exclusion chromatography (SEC) applications. It provides users with the necessary functionality to collect, process, and analyze chromatographic data.

Automatically generated - may contain errors

2 protocols using omnisec software v5

1

SEC Analysis of Protein Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Size exclusion chromatography experiments were performed with a HPLC pump (LC10AD, Shimadzu) coupled to an autosampler (Viscotek VE 2001, Malvern Panalytical) and a multi-detector system recording light scattering (RALS/LALS) intrinsic viscosity and refractive index signals (Viscotek TDA305, Malvern Panalytical). The HPLC SEC column (BioSec5 500 Å, 5 μm, 7.8 mm ID × 300 mm, void volume ∼6 mL, total volume ∼ 12.5 mL, Agilent) was equipped with a post-column nylon filter (0.22 μm). The column was equilibrated with PBS (pH 6.8) supplemented with sodium azide 0.02%. The flow rate and the temperature were 0.35 mL/min and 30°C respectively. Data were processed with the OmniSEC software (v5.12, Malvern Panalytical). The calibration procedure was done with BSA (Sigma) and cross-validation was performed with β-lactoglobulin (Sigma). The refractometer was used as the concentration detector and the refractive index increment value (dn/dc) used to determine the molecular weight was 0.185 mL/g. Samples were diafiltered in the aforementioned buffer and filtered through a 0.22 μm PES-filter just before injection.
+ Open protocol
+ Expand
2

SEC Characterization of Alginate Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
SEC experiments were performed with a HPLC pump (LC10AD, Shimadzu, Noisiel, France) coupled to an autosampler (Autosampler VE 2001, Malvern Panalytical, Palaiseau, France) and a multi-detector system recording UV, light scattering (RALS/LALS) intrinsic viscosity and refractive index signals (Viscotek TDA305, Malvern Panalytical, Palaiseau, France). One SEC column (A6000M, 10 or 13 μm, 8 mm ID × 300 mm, void volume ~6 mL, total volume ~12.5 mL, Malvern Panalytical, Palaiseau, France) was equipped with a post-column nylon filter (0.22 µm). The column was equilibrated with NaNO3 0.15 M, NaN3 0.02% and EDTA 0.01 M in ultrapure water. The flowrate was 0.7 mL·min−1 and the temperature was 30 °C. Data were processed with the Omnisec software (v5.12, Malvern Panalytical, Palaiseau, France). The calibration procedure was performed with bovine serum albumin, and cross-validations were performed with the PEO24k and Dextran standards. The refractometer was used as the concentration detector and the refractive index increment value (dn/dc) used to determine the molecular weight (Mw) was 0.150 mL/g [16 (link)]. Alginate samples were solubilized in the aforementioned buffer at 2 g·L−1 and filtered through a 0.22 µm PES filter shortly before injection (injection volume: 100 µL).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!