The TripleTOF 5600 Mass Spectrometer was used to acquire the MS/MS spectra on an information-dependent basis (IDA) with the acquisition software (Analyst TF 1.7, AB Sciex) to evaluate the full scan survey MS data. The most intensive 12 precursor ions with intensity > 100 were selected for MS/MS at collision energy (CE) of 45 eV. The ESI source conditions were set as follows: Gas 1 as 60 psi, Gas 2 as 60 psi, Curtain Gas as 30 psi, source temperature as 600℃, declustering potential as 100 V, and ion spray voltage floating (ISVF) as 5000 V or − 3800 V in positive or negative modes, respectively16 (link).
Exionlc infinity series uhplc system
The ExionLC Infinity series UHPLC System is a high-performance liquid chromatography (HPLC) instrument designed for ultra-high-performance liquid chromatography (UHPLC) applications. The system is capable of operating at high pressures, enabling the use of smaller particle size columns for improved resolution and faster separation times.
Lab products found in correlation
3 protocols using exionlc infinity series uhplc system
LC-MS/MS Analysis of Metabolites
The TripleTOF 5600 Mass Spectrometer was used to acquire the MS/MS spectra on an information-dependent basis (IDA) with the acquisition software (Analyst TF 1.7, AB Sciex) to evaluate the full scan survey MS data. The most intensive 12 precursor ions with intensity > 100 were selected for MS/MS at collision energy (CE) of 45 eV. The ESI source conditions were set as follows: Gas 1 as 60 psi, Gas 2 as 60 psi, Curtain Gas as 30 psi, source temperature as 600℃, declustering potential as 100 V, and ion spray voltage floating (ISVF) as 5000 V or − 3800 V in positive or negative modes, respectively16 (link).
UHPLC-QTOF-MS for Metabolite Profiling
TripleTOF 5600 mass spectrometry (AB Sciex) was used for its ability to acquire MS/MS spectra on an information-dependent basis (IDA) during LC/MS experiments. In this mode, the acquisition software (Analyst TF 1.7, AB Sciex) continuously evaluates the full scan survey MS data as it collects and triggers the acquisition of MS/MS spectra depending on preselected criteria. In each cycle, the most intensive 12 precursor ions with intensity above 100 were chosen for MS/MS at a collision energy (CE) of 30 eV. In the detection process, standard products and blank controls were strictly used for quality control, and data quality control was also carried out. The UHPLC-QTOF-MS analysis was performed at Biomarker Technologies Corporation, Beijing, China (
UHPLC-MS/MS Metabolomic Profiling Protocol
The TripleTOF 5600 mass spectrometer was used for MS/MS spectra detection on an informationdependent basis (IDA). In this mode, the most intensive 12 precursor ions with intensity above 100 were chosen for MS/MS at collision energy (CE) of 45 eV (12 MS/MS events with accumulation time of 50 msec each). ESI source conditions were set as following: Gas 1 as 60 psi, Gas 2 as 60 psi, Curtain Gas as 30 psi, Source Temperature as 600 ℃, Declustering potential as 100 V, Ion Spray Voltage Floating (ISVF) as 5000 V or -3800 V in positive or negative modes, respectively (22) .
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!