The largest database of trusted experimental protocols

X red

Manufactured by STOE

X-RED is a laboratory equipment designed for the analysis and detection of specific compounds or materials. It utilizes X-ray technology to perform rapid and accurate measurements. The core function of X-RED is to provide researchers and scientists with a reliable tool for their analytical needs.

Automatically generated - may contain errors

8 protocols using x red

1

Structural Analysis of Sr2Co3S2O3

Check if the same lab product or an alternative is used in the 5 most similar protocols
Single crystal x-ray diffraction of Sr2Co3S2O3 was performed in a Bruker Apex D8 Venture with a Mo-Kα (λ = 0.71073 Å) radiation at room temperature. The numerical absorption correction was completed by using XRED (v. 1.07, STOE & Cie GmbH) and X-shape (v. 1.01, STOE & Cie GmbH). The crystal structure was determined and refined by treating the single crystal x-ray diffraction data with the JANA2006 software35 . The powder x-ray diffraction was carried out in a focusing camera with a Co (λ = 1.78892 Å) radiation. The corresponding Rietveld refinement was also performed in JANA2006. Elemental analysis was conducted in an energy-dispersive x-ray spectroscopy (EDX) inside a scanning electron microscope (Philips SEM XL30).
+ Open protocol
+ Expand
2

Crystal Structure Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols

Stoe IPDS-2 diffractometer

Absorption correction: integration (X-RED; Stoe & Cie, 2011 ▶ ) Tmin = 0.614, Tmax = 0.860

15353 measured reflections

4133 independent reflections

3971 reflections with I > 2σ(I)

Rint = 0.047

+ Open protocol
+ Expand
3

Single Crystal X-Ray Diffraction

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: X-AREA (Stoe & Cie, 2011 ▶ ); cell refinement: X-AREA; data reduction: X-RED (Stoe & Cie, 2011 ▶ ); program(s) used to solve structure: SHELXS97 (Sheldrick, 2008 ▶ ); program(s) used to refine structure: SHELXL2013 (Sheldrick, 2008 ▶ ); molecular graphics: DIAMOND (Brandenburg, 2012 ▶ ) and ORTEP-3 for Windows (Farrugia, 2012 ▶ ); software used to prepare material for publication: SHELXL2013.
+ Open protocol
+ Expand
4

Crystal Structure Determination Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: X-AREA (Stoe & Cie, 2011 ▶ ); cell refinement: X-AREA; data reduction: X-RED (Stoe & Cie, 2011 ▶ ); program(s) used to solve structure: SHELXS97 (Sheldrick, 2008 ▶ ); program(s) used to refine structure: SHELXL2013 (Sheldrick, 2008 ▶ ); molecular graphics: DIAMOND (Brandenburg, 2012 ▶ ) and ORTEP-3 for Windows (Farrugia, 2012 ▶ ); software used to prepare material for publication: SHELXL2013 and PLATON (Spek, 2009 ▶ ).
+ Open protocol
+ Expand
5

Crystal Structure Determination by IPDS-2

Check if the same lab product or an alternative is used in the 5 most similar protocols

Stoe IPDS-2 diffractometer

Absorption correction: integration (X-RED; Stoe & Cie, 2011 ▶ ) Tmin = 0.758, Tmax = 0.955

17495 measured reflections

8918 independent reflections

6396 reflections with I > 2σ(I)

Rint = 0.044

+ Open protocol
+ Expand
6

Single Crystal X-ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: X-AREA (Stoe & Cie, 2010 ▶ ); cell refinement: X-AREA; data reduction: X-RED (Stoe & Cie, 2010 ▶ ); program(s) used to solve structure: SIR97 (Altomare et al., 1999 ▶ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▶ ); molecular graphics: PLATON (Spek, 2009 ▶ ); software used to prepare material for publication: PLATON.
+ Open protocol
+ Expand
7

Single Crystal X-Ray Diffraction Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: STADI4 (Stoe, 1998 ▶ ); cell refinement: STADI4; data reduction: X-RED (Stoe, 1998 ▶ ); program(s) used to solve structure: SHELXS97 (Sheldrick, 2008 ▶ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▶ ) and WinGX (Farrugia, 2012 ▶ ); molecular graphics: DIAMOND (Brandenburg, 2001 ▶ ) and ORTEP-3 for Windows (Farrugia, 2012 ▶ ); software used to prepare material for publication: enCIFer (Allen et al., 2004 ▶ ).
+ Open protocol
+ Expand
8

Single Crystal X-Ray Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Data collection: X-AREA (Stoe & Cie, 2011 ▶ ); cell refinement: X-AREA; data reduction: X-RED (Stoe & Cie, 2011 ▶ ); program(s) used to solve structure: SIR97 (Altomare et al., 1999 ▶ ); program(s) used to refine structure: SHELXL97 (Sheldrick, 2008 ▶ ); molecular graphics: PLATON (Spek, 2009 ▶ ); software used to prepare material for publication: PLATON.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!