19 protocols using precoated silica gel 60 f254

1

Synthesis and Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The melting points (in °C) were measured with a Stuart melting point apparatus and are uncorrected. Thermo Fisher SCIENTIFIC Nicolet IS10 Spectrometer (v in cm−1) was used to record IR spectra (KBr) at Mansoura University's Faculty of Pharmacy. At the NMR facility, Faculty of Pharmacy, Mansoura University, Egypt, 1H-NMR and 13C-NMR spectra were acquired in a BRUKER 400 MHz using TMS as an internal standard (chemical shifts in ppm, units). Thin layer chromatography (TLC) plates with Silica gel 60 F254 precoated (E. Merck) were used to monitor reaction completion, and the spots were seen using UV light (366 nm). Sigma-Aldrich provided all of the compounds, which were utilized without additional purification. Compounds 227 (link), 432 (link) and 639 were synthesized according to the previously reported procedures.
+ Open protocol
+ Expand
2

Synthesis and Characterization of 4-Thiazolidinone Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the solvents and regents were purchased from Sigma Aldrich (Gillingham, UK) and they were used in the reactions without purification. The progress of each reaction was monitored by ascending thin layer chromatography (TLC) using TLC aluminum sheets, silica gel 60F254 precoated (Merck, Darmstadt, Germany), and locating the spots using UV light as the visualizing agent or iodine vapor. The melting points for the 4-thiazolidinone conjugates were carried out using an open capillary method and they are uncorrected. 1H NMR spectra were obtained on a Bruker DRX-400 MHz NMR spectrometer in DMSO-d6 (δ in ppm relative to tetramethylsilane (TMS) as an internal standard) and 13C NMR spectra were recorded (DMSO-d6) on a Bruker DRX-100 MHz spectrometer (Bruker BioSpin MRI GmbH, Ettlingen, Germany). High-resolution mass spectra (HRMS) were obtained using an Agilent 6520 (QTOF) ESI-HRMS model (Thermo Fisher Scientific, Waltham, MA, USA).
+ Open protocol
+ Expand
3

Synthesis and Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All the chemicals were purchased from Sigma-Aldrich, and all the solvents for the use were of laboratory grade. The materials for in vitro evaluation were obtained from Sigma-Aldrich Ltd. The reactions were monitored by thin layer chromatography (TLC) on precoated silica gel 60 F254 (Merck, Darmstadt, Germany), and spots were visualized with UV light. Merck silica gel (80–120 mesh; Merck, Darmstadt, Germany) was used for column chromatography. All the synthesized compounds were purified by recrystallization and column chromatography. Melting points were determined via an open capillary method and were uncorrected. IR spectra were recorded on a Perkin-Elmer FT-IR 240-C Spectrophotometer using KBr optics (Perkin-Elmer, Waltham, MA, USA). Next, 1H-NMR spectra were recorded on Gemini Varian (Varian, Palo Alto, CA, USA) 200 MHz, Bruker (Bruker Bioscience, Billerica, MA, USA) AV 300 MHz, and Unity (Varian) 400 MHz spectrometer in DMSO-d6 or CDCl3 using TMS as an internal standard. Electron impact (EI) and chemical ionization mass spectra were recorded on a VG 7070 H instrument (Micromass, St Leonards-0n Sea, UK) at 70 eV.
+ Open protocol
+ Expand
4

Synthesis and Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
N-Hexane, chloroform, n-butanol and ethanol were purchased from Fisher Scientifics (UK). Silica Gel 60, xanthine oxidase, xanthine, allopurinol, and uric acid assay kit were purchased from Sigma (USA). All other chemicals were of analytical grade. Melting point was determined on Electrothermal 9100 equipment. Mass spectrum was measured on a Jeol Mass Spectrometer SSQ 7000, Digital DEC 300. NMR spectrum was measured in DMSO. 1H–NMR spectrum was obtained at 400 MHz on a JEOL GX-400 spectrometer with the chemical shifts (δ ppm) expressed relative to TMS as internal standard. Precoated Silica Gel 60 F254 (Merck, Darmstadt, Germany) was used for the TLC analysis. Vacuum liquid chromatography (VLC) was performed on Silica Gel 60 GF (Merck, Darmstadt, Germany)
+ Open protocol
+ Expand
5

Characterization of Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
Nuclear magnetic resonance (NMR) experiments were performed on a JEOL ECX-500 spectrometer (1H, 500 MHz; 13C, 125 MHz; JEOL Ltd., Japan). All chemical shifts were referenced relative to the corresponding signals (δH 3.31/δC 49.15 for CD3OD). Electron ionization mass spectrometer (EI-MS) data were obtained using micromass spectrum (AUTOSPEC, UK). High performance liquid chromatography (HPLC) was performed using Agilent 1200 series (Agilent Technologies, CA, USA). Open column chromatography (CC) was carried out over a silica gel 60 (70–230 mesh, 230–400 mesh ASTM, Merck, Darmstadt, Germany) and sephadex LH-20 gel (GE Healthcare, Uppsala, Sweden). Pre-coated silica gel 60 F254 (Merck) were used for thin-layer chromatography (TLC).
+ Open protocol
+ Expand
6

NMR Spectroscopy and Mass Spectrometry Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Nuclear magnetic resonance (NMR) experiments were performed on a JEOL ECX-500 spectrometer (1H, 500 MHz; 13C, 125 MHz; JEOL Ltd., Japan). All chemical shifts were referenced relative to the corresponding signals (δH 3.31/δC 49.15 for CD3OD). EI-MS data were obtained using micromass spectrum (AUTOSPEC, UK). High-performance liquid chromatography (HPLC) was performed using the Agilent 1200 series (Agilent Technologies, CA, USA). Open column chromatography (CC) was carried out over a silica gel 60 (70–230 mesh, 230–400 mesh ASTM, Merck, Darmstadt, Germany) and sephadex LH-20 gel (GE Healthcare, Sweden). Pre-coated silica gel 60 F254 (Merck) were used for thin-layer chromatography (TLC).
+ Open protocol
+ Expand
7

Spectroscopic and Chromatographic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Shimadzu 1700 spectrophotometer was used for UV absorption spectra. Melting points were determined on Electrothermal 9100 equipment. Mass spectra were measured on a Jeol Mass Spectrometer SSQ 7000, Digital DEC 300. NMR spectra were measured in DMSO or CD3OD or CDCl3; 1H–NMR spectra were obtained at 400 MHz and 13 C-NMR spectra at 100 MHz on a JEOL GX-400 spectrometer with the chemical shifts (δ ppm) expressed relative to TMS as internal standard. Pre-coated silica gel 60 F254 (Merck, Darmstadt, Germany) was used for the TLC analysis. Vacuum liquid chromatography (VLC) was performed on silica gel 60 GF (Merck, Darmstadt, Germany). Sephadex LH-20 (Sigma-Aldrich, St. Louis, Missouri, United States) and silica gel 100 C18-Reversed Phase (Fluka, Switzerland) were also used. Analysis of phenolics was performed on Hewlett Packard HPLC (HP 1050HPLCDADw/Data System) equipped with a Hypersil-ODS (4.6 X 250 mm, 5 μm) column and a UV detector.
+ Open protocol
+ Expand
8

Synthesis and Characterization of Triaminopyrimidine-bisamidinium Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
Triaminopyrimidine-bisamidinium conjugates were synthesized following Scheme S1. 1H NMR spectra were recorded on a Varian Unity Inova 500 spectrometer. All NMR measurements were carried out in DMSO-d6 at room temperature unless otherwise stated. Chemical shifts were reported as parts per million (ppm). Mass spectra were obtained in the Mass Spectrometry Laboratory, School of Chemical Sciences, University of Illinois. The analytical HPLC traces was obtained using a C18 column with the eluent of 0.1% TFA (v/v) in 1:1 MeOH-water as eluent.
All reactions were carried out under a nitrogen atmosphere. All solvents and reagents were purchased commercially with a reagent quality and used without further purification. The progress of reaction was monitored by thin layer chromatography (TLC) using Merck pre-coated silica gel 60F254.
+ Open protocol
+ Expand
9

Analytical Techniques for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were recorded on a Bruker AM500 FT-NMR spectrometer using TMS as an internal Standard. HR-ESI-MS were recorded on an Agilent 6530 accurate mass QTOF LC/MS systems. Column chromatography (CC) was performed using Kieselgel 60, 70-230 mesh and 230-400 mesh (Merck, Darmstadt, Germany). Thin layer chromatography (TLC) used pre-coated silica gel 60 F254 (Merck, Darmstadt, Germany); compounds were visualized by spraying with aqueous 10% H 2 SO 4 and heating for 3-5 minutes. Preparative HPLC were carried out on an Agilent 1100 system (Agilent technologies, Santa Clara, CA, USA), using J'sphere ODS-H80 semi-preparative column (20×250 mm, YMC, Kyoto, Japan).
+ Open protocol
+ Expand
10

Spectroscopic Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were determined on a JASCO P-2000 polarimeter (Hachioji, Tokyo, Japan). CD spectra were recorded with a Chirascan spectropolarimeter (Applied Photophysics, Leatherhead, UK). High-resolution electrospray ionization mass spectrometry (ESI-MS) analysis was conducted on an Agilent 6530 Accurate-Mass Q-TOF LC/MS system (Agilent Technologies, Palo Alto, CA, USA). NMR spectra were recorded on Bruker AM600 FT-NMR and Bruker BioSpin 400 NMR spectrometers (Rheinstetten, Germany). Column chromatography (CC) was performed on silica gel (Kiesel gel 60, 70–230 mesh and 230–400 mesh, Merck, Darmstadt, Germany), YMC*GEL (ODS-A, 12 nm S-150 μm, YMC, Kyoto, Japan) and Sephadex LH-20 (Sigma-Aldrich, St. Louis, MO, USA) resins. Precoated silica gel 60 F254 (1.05554.0001, Merck, Darmstadt, Germany) and RP-18 F254S plates (1.15685.0001, Merck) were used for TLC. Preparative high-performance liquid chromatography (HPLC) separations were carried out using a Shimadzu LC-6AD (Shimadzu, Kyoto, Japan) instrument with a YMC-Pack ODS-A column (20 mm I.D. × 250 mm, S-5 μm) and an SPD-20A wavelength detector set at 210 nm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!