Agilent 1200 series diode array

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 1200 Series diode array is a high-performance liquid chromatography (HPLC) detector. It utilizes a diode array to provide full spectral information for each detected compound, enabling enhanced analyte identification and quantification.

Automatically generated - may contain errors

2 protocols using agilent 1200 series diode array

1

Structural Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations ( [α]D25 ) were measured on an Anton Paar MCP 200 Modular Circular Polarimeter (Anton Paar GmbH, Graz, Austria) in a 100 × 2 mm cell. CD spectra were recorded on an Applied Photophysics Chirascan spectropolarimeter (Applied Photophysics Ltd., Leatherhead, UK). NMR spectra were obtained on a Bruker Avance 500 spectrometer (Bruker BioSpin Corp., Billerica, MA, USA) with residual solvent peaks as references (DMSO-d6: δH 2.50, δC 39.52; acetone-d6: δH 2.05, δC 29.84; CDCl3: δH 7.26, δC 77.16). High-resolution ESIMS measurements were obtained on an Accurate-Mass-Q-TOF LC/MS 6520 instrument (Agilent Technologies, Santa Clara, CA, USA) in positive ion mode. HPLC was performed using an Agilent 1200 Series separation module equipped with an Agilent 1200 Series diode array and Agilent 1260 Series fraction collector (Agilent Technologies, Santa Clara, CA, USA), and an Agilent ZORBAX SB-C18 column (250 × 9.4 mm, 5 µm).
+ Open protocol
+ Expand
2

Optical and Spectroscopic Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations ([α ]D25 ) were measured on an Anton Paar MCP 200 Modular Circular Polarimeter (Austria) in a 100 × 2 mm cell. CD spectra were recorded on an Applied Photophysics Chirascan spectropolarimeter (Surrey, UK). NMR spectra were obtained on a Bruker Avance 500 spectrometer with residual solvent peaks as references (DMSO-d6: δH 2.50, δC 39.52). High-resolution ESIMS measurements were obtained on an Accurate-Mass-Q-TOF LC/MS 6520 instrument (Santa Clara, CA, USA) in the positive ion mode. HPLC was performed using an Agilent 1200 Series separation module equipped with an Agilent 1200 Series diode array, Agilent 1260 Series fraction collector, and Agilent ZORBAX SB-C18 column (250 × 9.4 mm, 5 µm).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!