Esi q tof ms ms 6520 instrument

Manufactured by Agilent Technologies
Sourced in United States

The ESI-Q-TOF MS/MS 6520 instrument is a high-resolution mass spectrometer that utilizes electrospray ionization (ESI) and quadrupole time-of-flight (Q-TOF) technology. It is designed to provide accurate mass measurements and high-quality MS/MS data for a wide range of analytes.

Automatically generated - may contain errors

2 protocols using esi q tof ms ms 6520 instrument

1

Metabolomic Analysis using LC-ESI-QTOF

Check if the same lab product or an alternative is used in the 5 most similar protocols
For the metabolomic analysis, an Agilent 1290 LC system coupled to an ESI-Q-TOF MS/MS 6520 instrument (Agilent Technologies, Barcelona, Spain) was used. In all cases, 2 μL of extracted sample were applied onto a reversed-phase column (Zorbax SB-Aq 1.8 μm 2.1 × 50 mm; Agilent Technologies, Barcelona, Spain) equipped with a precolumn (Zorba-SB-C8 Rapid Resolution Cartridge 2.1 × 30 mm 3.5 μm; Agilent Technologies, Barcelona, Spain) with a column temperature of 60 °C. The flow rate was 0.6 mL/min. Solvent A was composed of water containing 0.2% acetic acid, and solvent B was composed of methanol 0.2% acetic acid. The gradient started at 2% B and increased to 98% B in 13 min and held at 98% B for 6 min. Pot-time was set at 5 min. Data were collected in positive electrospray mode, with the TOF operated in full-scan mode at 50–1600 m/z in an extended dynamic range (2 GHz) using N2 as the nebuliser gas (10 L/min, 350 °C). The capillary voltage was 4000 V, with a scan rate of 1.5 scan/s. The ESI source used a separate nebuliser for the continuous, low-level (10 L/min) introduction of reference mass compounds: 121.050873 and 922.009798 (positive ion mode) and 119.036320 and 966.000725 (negative ion mode), which were used for continuous, online mass calibration.
+ Open protocol
+ Expand
2

Targeted Metabolomics Profiling Using LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
After snap-freezing, samples were homogenized in 1:20 w:v cold methanol (-20ºC) with 1 mM butylated hydroxytoluene and centrifuged at 13,000g for 10 min at 4ºC. The supernatant was stored at -80ºC until Mass Spectrometry (MS) analysis. 2μL of extracted sample was injected into an Agilent 1290 LC system coupled to an ESI-Q-TOF MS/MS 6520 instrument (Agilent, California, USA). MassHunter Data Analysis Software (Agilent) was used to collect the results.
MassHunter Mass Profiler Professional Software (Agilent) was used to perform a non-targeted metabolomics analysis of the samples.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!