The largest database of trusted experimental protocols

Cd138 fitc pe apc

Manufactured by BD
Sourced in United States

CD138-FITC/PE/APC is a laboratory reagent used for the detection and identification of CD138-positive cells in biological samples. It consists of fluorescently-labeled antibodies that bind to the CD138 antigen, which is expressed on the surface of plasma cells and some other cell types. The reagent can be used in flow cytometry applications to analyze the presence and relative abundance of CD138-positive cells in a sample.

Automatically generated - may contain errors

4 protocols using cd138 fitc pe apc

1

Investigating MM-pDC Interactions and Immunotherapies

Check if the same lab product or an alternative is used in the 5 most similar protocols
MM cells were cultured in 10% FBS plus RPMI-1640 medium supplemented with antibiotics. MM–pDCs were cocultured either in DCP-MM medium (Mattek Corp., Ashland, MA) or complete RPMI-1640 medium supplemented with IL-3 (Peprotech Inc., Rocky Hill, NJ, USA). CD3-PE/FITC/APC; CD4-FITC/PE or APC-Cy7; CD8-APC/FITC, CD56-PE; CD123-PE/PE-Cy5/FITC; and CD138-FITC/PE/APC were obtained from BD Biosciences (San Jose, CA). BDCA-2-FITC and CD11c-APC were obtained from Miltenyi Biotec (Auburn, CA); CD303-; CD304-; CD107a; and PD-L1-BV421 were purchased from Biolegend. All immunomagnetic separation kits were purchased from Miltenyi Biotec. The CellTrace Violet and CellTracker Green flow assay kits were obtained from Life Technologies (USA). Functional-grade PD-L1 blocking antibody (antihuman PD-L1, clone MIH1) was obtained from eBiosciences [4 (link)]. Ro 61–8048 [13 (link)] and INCB 024360 were purchased from Selleck Chemicals. WST-1 Cell Proliferation Reagent was purchased from Clontech Laboratories, Inc. (USA).
+ Open protocol
+ Expand
2

Immunophenotyping and Drug Screening

Check if the same lab product or an alternative is used in the 5 most similar protocols
MM cell lines and PBMCs from normal healthy donors were cultured in RPMI-1640 medium supplemented with 10% FBS and antibiotics. Human recombinant IL-3 was purchased from Peprotech Inc (Rocky Hill, NJ, USA). CD3-PE; CD4-FITC or APC-Cy7; CD8-APC, CD123-PE/PE-Cy5/FITC; CD138-FITC/PE/APC; CD133-PE and CD27-Alexa-700 were obtained from BD Biosciences (San Jose, CA, USA). HLA-DR Violet Blue, CD303 (BDCA-2)-FITC, CD14-PE, and CD11c-APC were purchased from Miltenyi Biotec (Auburn, CA, USA); CD304-BV421 was obtained from Biolegend. All immunomagnetic separation kits were purchased from Miltenyi Biotec. Bortezomib, lenalidomide, SAHA, dexamethasone and pomalidomide were purchased from Selleck Chemicals, LLC (Houston, TX, USA).
+ Open protocol
+ Expand
3

Coculture of Myeloid Dendritic Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
MM-pDCs were cocultured either in DCP-MM medium (Mattek Corp. Ashland, MA) or complete RPMI-1640 medium supplemented with IL-3 (Peprotech Inc., Rocky Hill, NJ, USA). CD3-PE/FITC/APC; CD4-FITC/PE or APC-Cy7; CD8-APC/FITC, CD56-PE; CD123-PE/PE-Cy5/FITC; and CD138-FITC/PE/APC were obtained from BD Biosciences (San Jose, CA). BDCA-2-FITC and CD11c-APC were obtained from Miltenyi Biotec (Auburn, CA); CD303-, CD304-, CD107a, and PD-L1-BV421 were purchased from Biolegend. Immunomagnetic separation kits were purchased from Miltenyi Biotec. The CellTrace Violet and CellTracker Green flow assay kits were obtained from Life Technologies (USA). PD-L1 blocking antibody (anti-human PD-L1, clone MIH1) was obtained from eBiosciences [19 (link)]. HDAC6 inhibitor ACY241 and ENO inhibitor (ENOblock) [40 (link)] were purchased from Selleck Chemicals. WST-1 Cell Proliferation Reagent was purchased from Clontech Laboratories, Inc. (USA).
+ Open protocol
+ Expand
4

Plasmacytoid Dendritic Cell Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
MM-pDCs were co-cultured either in DCP-MM medium (Mattek Corp. Ashland, MA) or complete RPMI-1640 medium supplemented with IL-3 (Peprotech Inc., Rocky Hill, NJ, USA). CD3-PE/FITC/APC; CD4-FITC/PE or APC-Cy7; CD8-APC/FITC, CD56-PE; CD123-PE/PE-Cy5/FITC; and CD138-FITC/PE/APC were obtained from BD Biosciences (San Jose, CA). BDCA-2-FITC and CD11c-APC were obtained from Miltenyi Biotec (Auburn, CA); CD303-, CD304-, CD107a, CD138-BV421, and PD-L1-BV421 were purchased from Biolegend. Immunomagnetic separation kits were purchased from Miltenyi Biotec. The CellTrace Violet and CellTracker Violet/Green flow assay kits were obtained from Life Technologies (USA). CD73 blocking antibody (anti-human CD73 Abs) and TLR-7 agonist were obtained from eBiosciences and Invivogen, respectively. WST-1 Cell Proliferation Reagent was purchased from Clontech Laboratories, Inc. (USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!