The largest database of trusted experimental protocols

Shodex kw 402.5 4f

Manufactured by Resonac

The Shodex KW-402.5-4F is a size exclusion chromatography (SEC) column used for the analysis of macromolecules, such as proteins, polymers, and other large molecules. It is designed with a column diameter of 4.6 mm and a bead size of 5 µm. The column is typically used for the separation and purification of these types of analytes.

Automatically generated - may contain errors

2 protocols using shodex kw 402.5 4f

1

Characterization of MATCH Chain Dimerization

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

Efficient MATCH chain dimerization was further demonstrated by the remarkable homogeneity of the protein content in protein L-purified samples. The protein was analyzed over the course of four weeks and storage at 4° C. and 37° C. with respect to oligomerization by SE-HPLC and degradation by SDS-PAGE (see FIGS. 7 to 9). Prior to the study the sample concentration was adjusted to 1 g/L and t0 time points were determined. The monomer content was quantified by separation of the samples on a Shodex KW-402.5-4F (Showa Denko) and evaluation of the resulting chromatograms. For the calculation of the relative percentage of protein monomer the area of the monomeric peak was divided by the total area of peaks that could not be attributed to the sample matrix. The protein degradation was assessed by SDS-PAGE analysis with Any kD Mini-Protean TGX gels (Bio-Rad Laboratories) and stained with Coomassie brilliant blue. The protein concentration was monitored at the different time points by UV-Vis spectroscopy with an Infinity reader M200 Pro equipped with Nanoquant plate (Tecan Group Ltd.).

+ Open protocol
+ Expand
2

Stability Assessment of MATCH Protein

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 3

Efficient MATCH chain dimerization was further demonstrated by the remarkable homogeneity of the protein content in protein L-purified samples. The protein was analyzed over the course of four weeks and storage at 4° C. and 37° C. with respect to oligomerization by SE-HPLC and degradation by SDS-PAGE (see FIGS. 7 to 9). Prior to the study the sample concentration was adjusted to 1 g/L and t0 time points were determined. The monomer content was quantified by separation of the samples on a Shodex KW-402.5-4F (Showa Denko) and evaluation of the resulting chromatograms. For the calculation of the relative percentage of protein monomer the area of the monomeric peak was divided by the total area of peaks that could not be attributed to the sample matrix. The protein degradation was assessed by SDS-PAGE analysis with Any kD Mini-Protean TGX gels (Bio-Rad Laboratories) and stained with Coomassie brilliant blue. The protein concentration was monitored at the different time points by UV-Vis spectroscopy with an Infinity reader M200 Pro equipped with Nanoquant plate (Tecan Group Ltd.).

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!