The largest database of trusted experimental protocols

Tricorn series columns

Manufactured by Cytiva

The Tricorn™ series columns are high-performance chromatography columns designed for use in a wide range of purification applications. These columns feature a unique three-piece construction for enhanced performance and reliability.

Automatically generated - may contain errors

4 protocols using tricorn series columns

1

Protein A Affinity Chromatography

Check if the same lab product or an alternative is used in the 5 most similar protocols
1 mL and 5 mL of MabSelect PrismA (Cytiva) resin were packed in Tricorn™ series columns (Cytiva) with a bed height of 5.1 cm and 6.4 cm, respectively, with experiments conducted on an AKTA™ Avant 25 (Cytiva). All columns were equilibrated with 100 mM sodium phosphate, 150 mM NaCl, pH 7.2, before loading the appropriate amount of CCS. A 3 CV wash of 50 mM Na-citrate, pH 6.0 was performed after loading of CCS for all experiments. All elution buffers contain 50 mM Na-citrate at their respective pH between 6.0 and 3.0. The pH values of collected eluates were measured using an external pH probe (Mettler Toledo), where necessary.
+ Open protocol
+ Expand
2

Purification Chromatography Using AKTA Avant 25

Check if the same lab product or an alternative is used in the 5 most similar protocols
All purification chromatography was conducted on an AKTA™ Avant 25 (Cytiva). 1 mL and 5 mL of the respective resins was packed in Tricorn™ series columns (Cytiva) with a bed height of 5.1 cm and 6.4 cm, respectively.
Capto Butyl ImpRes was equilibrated with 50 mM Na-citrate, pH 4.0, before loading the appropriate amount of sample. A 20 column volume (CV) wash with the same equilibration buffer was applied and flow-through > 50 mAu was collected for analysis. Capto adhere was equilibrated with 50 mM Na-citrate, pH 6.5 or pH 6.8, before loading the appropriate amount of sample. A 25 CV wash at the same pH was applied and both the flow-through during loading and 25 CV wash were collected. Capto S ImpAct was equilibrated with 20 mM citric acid and 20 mM sodium phosphate, pH 5.5, 50 mM NaCl, before loading the appropriate amount of sample. A 3 CV wash of equilibration buffer was performed followed by a linear gradient from equilibration buffer to the same buffer with 500 mM NaCl in 20 CV, with a 5 CV hold at the end. 4 min residence time was utilised for all polishing resins.
+ Open protocol
+ Expand
3

Affinity Chromatography Protein Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Unless otherwise stated, all buffers, salts and reagents were purchased from Merck Millipore. MabSelect PrismA (Cytiva) resin as well as Tricorn™ series columns (Cytiva) was kindly provided by Cytiva.
+ Open protocol
+ Expand
4

Optimized bsAb Purification Workflow

Check if the same lab product or an alternative is used in the 5 most similar protocols
Unless otherwise stated, all buffers, salts and reagents were purchased from Merck Millipore. All resins, PreDictor plates and Tricorn™ series columns (Cytiva) were kindly provided by Cytiva. bsAb culture and post-Protein A eluates were obtained as described previously (Chen et al. 2022 (link)).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!

  Request a quote for « Tricorn series columns »