The largest database of trusted experimental protocols

41 protocols using gf254

1

Spectroscopic Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Electrospray ionization mass spectra (ESI-MS) and high-resolution electrospray ionization mass spectra (HR-ESI-MS) were acquired using a high-resolution Q Exactive Focus Mass Spectrometer (Thermo Fisher Scientific, Bremen, Germany). Optical rotation measurements were conducted using a Jasco DIP-370 digital polarimeter (JASCO, Tokyo, Japan). Ultraviolet (UV) spectra were recorded using a Shimadzu UV-2401PC spectrophotometer. Nuclear magnetic resonance (NMR) spectra were recorded using an Avance III-600 spectrometer (Bruker BioSpin, Rheinstetten, Germany) using tetramethylsilane as an internal standard. Column chromatography was performed using silica gel (200–300 mesh), GF254 (Qingdao Marine Chemical Inc., Qingdao, China), and Sephadex LH-20 (Amersham Pharmacia, United Kingdom). Semipreparative high-performance liquid chromatography (HPLC) was performed using an LC3000 system (Beijing Chuangxintongheng Science and Technology Co., Ltd., Beijing, China). Precoated silica gel GF254 plates (Qingdao Marine Chemical Factory, Qingdao, China) were used for thin-layer chromatography (TLC) analysis.
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The HR-ESI-MS data were obtained on an Agilent 6210 time of flight LC-MS instrument (Agilent Technologies Inc., Palo Alto, CA, USA). NMR experiments were conducted on a Bruker DPX-400 NMR spectrometer (400 MHz for 1H NMR and 100 MHz for 13C NMR) or Bruker DRX-600 spectrometer (600 MHz for 1H NMR and 150 MHz for 13C NMR) (Bruker Corporation, Karlsruhe, Germany). The chemical shifts were given in δ (ppm) and referenced to the solvent signal (DMSO-d6, δH 2.50, δC 39.5; acetone-d6, δH 2.05, δC 29.8). Column chromatography (CC) was accomplished on silica gel (200–300 mesh, Qingdao Marine Chemical Inc., Qingdao, China), ODS (40–70 µm, Merck Company, Darmstadt, Germany) and Sephadex LH-20 (GE Healthcare Bio-Sciences AB, Uppsala, Sweden). Semi-preparative reverse-phase (RP) HPLC was performed on a Hitachi HPLC system with a L-7110 pump, a L-7420 UV/vis detector and an Hypersil RP-C18 column (5 µm, 250 × 10.0 mm, Thermo Fisher Scientific, Waltham, MA, USA). Thin-layer chromatography (TLC) was conducted on silica gel GF254 (10–20 µm, Qingdao Marine Chemical Inc., Qingdao, China). All chemicals used were of HPLC grade or analytical grade.
+ Open protocol
+ Expand
3

Isolation and Characterization of Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were obtained with a Jasco P-1020 Automatic Digital Polariscope. UV spectra were measured with a Shi madzu UV2401PC spectrometer. IR spectra were obtained on a Bruker FT-IR Tensor-27 infrared spectrophotometer with KBr pellets. 1H, 13C, and 2D NMR spectra were recorded on a Bruker DRX-400 NMR, Bruker DRX-500 NMR and Bruker DRX-600 spectrometer with TMS as internal standard. ESI-MS and HR-EI-MS analysis were carried out on Waters Xevo TQS and Waters AutoSpec Premier P776 mass spectrometers, respectively. Semi-preparative HPLC was performed on a Waters 600 HPLC with a COSMOSIL 5C18 MS-II (10ID × 250 mm) column. Silica gel (100–200 and 200–300 mesh, Qingdao Marine Chemical Co. Ltd., P.R. China), Sephadex LH-20 (GE Healthcare Bio-Xciences AB), RP-18 gel (20–45 μm, Fuji Silysia Chemical Ltd., Japan), and MCI gel (75–150 μm, Mitsubishi Chemical Corporation, Tokyo, Japan) were used for column chromatography. Fractions were monitored by TLC (GF 254, Qingdao Marine Chemical Co., Ltd., Qingdao), and spots were visualized by Dragendorff’s reagent.
+ Open protocol
+ Expand
4

Synthesis and Characterization of Tetrandrine

Check if the same lab product or an alternative is used in the 5 most similar protocols
Tetrandrine (purity ≥98%) was purchased from Nanjing Jingzhu Biotechnology Co., Ltd. (Nanjing, China). All reagents and solvents were sourced from commercial companies, Adamas (Shanghai, China) and Energy & Chemical (Shanghai, China), and used without additional purification unless otherwise stated. Anhydrous dichloromethane (DCM) was dried over calcium hydride prior to distillation under an argon atmosphere. Column chromatograph was filled with 300–400 mesh silica gel (Qingdao Marine Chemical Co., Ltd, Qingdao, China) and eluted using a mixture of dichloromethane, methanol, and diethylamine. Thin layer chromatography (TLC; 0.25 mm; GF254; Qingdao Marine Chemical Co., Ltd, Qingdao, China) was used to monitor the reactions, and UV light (254 nm) or 10% phosphomolybdic acid/ethanol was used for visualization. Bruker AVANCE III 600 MHz spectrometers (Bruker Biospin, Billerica, United States) were used to collect the nuclear magnetic resonance (NMR) spectra (1H, 13C, and 19F). High-resolution mass spectra were obtained using Thermo Scientific Q Exactive Focus (Thermo Scientific Q Exactive Focus). Melting points were determined using a WRX-4 micro melting point instrument (Tansoole, Shanghai, China).
+ Open protocol
+ Expand
5

Analytical Methods for Natural Product Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
1D and 2D NMR spectra were recorded on Bruker DRX-500 spectrometers using TMS as an internal standard. Chemical shifts (δ) were expressed in ppm with reference to the solvent signals. Optical rotations were measured on a JASCO P-1020 polarimeter. IR spectra were determined on a Bruker FT-IR Tensor-27 infrared spectrophotometer with KBr disks. UV spectra were detected on a SHMADZU UV-2401PC spectrometer. MS and HRMS analysis were carried out on Waters Xevo TQS and Waters AutoSpec Premier P776 mass spectrometers, respectively. Semipreparative HPLC was performed on a Waters 600 with a COSMOSIL C18 (10 × 250 mm) column. Silica gel (100–200 and 200–300 mesh, Qingdao Marine Chemical Co., Ltd., People’s Republic of China), and MCI gel (75–150 μm, Mitsubishi Chemical Corporation, Tokyo, Japan) were used for column chromatography. Fractions were monitored by thin-layer chromatography (TLC) (GF254, Qingdao Marine Chemical Co., Ltd.), and spots were visualized by 10% sulfuric acid ethanol solution.
+ Open protocol
+ Expand
6

Analytical Techniques for Natural Product Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
The UV spectrum was recorded on a Shimadzu UV-2600 PC spectrometer (Shimadzu, Beijing, China). The IR spectrum was obtained using an IR Affinity-1 spectrometer (Shimadzu). Optical rotations were determined with an Anton Paar MPC 500 polarimeter. HRESIMS spectra were recorded with a Bruker maXis Q-TOF mass spectrometer. The NMR spectra were recorded on a Bruker Avance-500 spectrometer (Bruker BioSpin International AG, Fällanden, Switzerland), and chemical shifts were recorded as δ-values. Semipreparative high-performance liquid chromatography (HPLC) was performed on the Hitachi Primaide with a DAD detector, using an ODS column (YMC-pack ODS-A, 10 × 250 mm, 5 μm). Thin-layer chromatography analysis (TLC) and column chromatography (CC) were carried out on plates precoated with silica gel GF254 (10–40 μm) and over silica gel (200–300 mesh) (Qingdao Marine Chemical Factory, Qingdao, China) and Sephadex LH-20 (Amersham Biosciences, Uppsala, Sweden), respectively. Spots were detected on TLC (Qingdao Marine Chemical Factory) under 254 nm UV light. All solvents employed were of analytical grade (Tianjin Fuyu Chemical and Industry Factory, Tianjin, China).
+ Open protocol
+ Expand
7

Structural Elucidation of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
UV spectra were measured on a Shimadzu UV-2600 PC spectrophotometer (Shimadzu, Kyoto, Japan). Optical rotations were recorded on a PerkinElmer MPC 500 (Waltham, MA, USA) polarimeter. For ECD spectra, Chirascan circular dichroism spectrometer (Applied Photophysics, Leatherhead Surrey, UK) was used. NMR spectra were acquired by a Bruker Avance spectrometer (Bruker, Billerica, MA, USA) at 700 MHz for 1H and 175 MHz for 13C. HRESIMS spectra were recorded on a Bruker miXis TOF-QII mass spectrometer (Bruker, Billerica, MA, USA). X-ray diffraction intensity data were measured on an Agilent Xcalibur Nova single-crystal diffractometer (Santa Clara, CA, USA) using Cu Kα radiation. TLC and column chromatography were performed on plates precoated with silica gel GF254 (10–40 μm) and over silica gel (200–300 mesh) (Qingdao Marine Chemical Factory, Qingdao, China), respectively. Spots were detected on TLC (Qingdao Marine Chemical Factory, Qingdao, China) under 254 nm UV light. Semi-preparative HPLC was performed using an ODS column (YMC-pack ODS-A, YMC Co., Ltd., Kyoto, Japan, 10 mm × 250 mm, 5 μm).
+ Open protocol
+ Expand
8

Spectroscopic Analysis of Fladins B, C, and D

Check if the same lab product or an alternative is used in the 5 most similar protocols
One-dimensional and two-dimensional NMR spectra of fladins B and D were recorded on a JEOL JNM-ECS400 (400 MHz) spectrometer (JEOL, Tokyo, Japan), and those of fladin C were recorded on a JEOL ECX 500M (500 MHz) spectrometer (JEOL, Tokyo, Japan). Chemical shifts (δ) were expressed in ppm, and coupling constants (J) were reported in Hz. All NMR experiments were obtained by using standard pulse sequences supplied by the vendor. Optical rotation was measured with a Perkin-Elmer model 241 polarimeter (Perkin Elmer, Waltham, MA, USA). IR spectra were recorded on a Bruker VECTOR22 spectrophotometer (Bruker, Rheinstetten, Germany) with KBr pellets. High-resolution electrospray ionization mass spectroscopy (HR-ESI-MS) was recorded on a VG Autospec-3000 spectrometer (VG, Manchester, England). Column chromatography was performed with silica gel (200–300 mesh; Qingdao Marine Chemical, Inc., Qingdao, China). Thin-layer chromatography (TLC) was performed on glass plates coated with silica gel GF254 (Qingdao Marine Chemical Inc.). All solvents, including petroleum ether (60–90 °C), were distilled prior to use. X-ray crystallographic data were obtained on a Bruker APEX-II CCD instrument (Bruker, Rheinstetten, Germany) using Cu Kα radiation.
+ Open protocol
+ Expand
9

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Nuclear magnetic resonance (NMR) spectra were recorded on a Bruker AV-500 at 500 MHz for the 1H NMR and 13C NMR (Bruker, Bremen, Germany). Chemical shifts (δ) were given in parts per million (ppm) with reference to the solvent signals, and coupling constants were measured in hertz. Optical rotation was recorded on an Autopol VI polarimeter (Rudolph, US). Column chromatography (CC) was done using silica gel (200–300 mesh, Qingdao Marine Chemical Co. Ltd., China). Thin layer chromatography (TLC) was performed on silica gel GF254 (Qingdao Marine Chemical Co. Ltd., China), and spots were visualized by heating silica gel plates sprayed with 1% vanillin and 10% H2SO4 in ethanol.
+ Open protocol
+ Expand
10

Detailed Analytical Techniques for Chemical Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
IR spectra were measured on a Bruker FT-IR Tensor-27 infrared spectrophotometer with KBr disks. Optical rotations were recorded on a JASCO P-1020 polarimeter. UV spectra were obtained with a Shimadzu UV-2401PC spectrometer. 1D and 2D NMR spectra were performed on a Bruker DRX-600 spectrometer using TMS as an internal standard. The chemical shifts (δ) were expressed in ppm with reference to the solvent signals. HREIMS and HRESIMS analysis were obtained from Waters Xevo TQS and Agilent G6230 TOF mass spectrometers, respectively. Single-crystal X-ray diffraction data were exhibited on a Bruker D8 QUEST diffractometer. Semi-preparative HPLC was performed on a Waters 1525 HPLC with a ZORBAX SB-C18 (9.4 × 250 mm) column. Silica gel (100–200 and 200–300 mesh, Qingdao Marine Chemical Co., Ltd., People’s Republic of China), and MCI gel (75–150 μm, Mitsubishi Chemical Corporation, Tokyo, Japan) were used for column chromatography. Fractions were monitored by TLC (GF 254, Qingdao Marine Chemical Co., Ltd.), and spots were visualized by heating Silica gel plates immersed in 10% H2SO4 in ethanol. Methanol (HPLC grade) and acetonitrile (HPLC grade) was purchased from CINC High Purity Solvents Co., Ltd (Shanghai, China). 4-Nitrophenyl-α-d-glucopyranoside (PNPG), α-glucosidase, PTP1B assay kit, quercetin, and acarbose were purchased from Sigma Chemical (Merck KGaA, Darmstadt, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!