The largest database of trusted experimental protocols

Amh gen 2 elisa assay kit

Manufactured by Beckman Coulter

The AMH Gen II ELISA assay kit is a quantitative immunoassay designed to measure the concentration of Anti-Müllerian Hormone (AMH) in human serum and plasma samples. This kit utilizes the enzyme-linked immunosorbent assay (ELISA) principle to provide precise and accurate measurements of AMH levels.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using amh gen 2 elisa assay kit

1

Longitudinal Serum AMH Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
A subset of premenopausal NHSII participants who gave blood samples in the initial collection also provided two additional sets of samples over the following 2 to 3 years. Mid-luteal blood samples from 113 of these women, chosen randomly, were assayed for AMH at the Sluss laboratory (Massachusetts General Hospital, Boston MA) using the AMH Gen II Elisa assay kit (Beckman Coulter) (CV=14.5%). These data were used to assess reproducibility over time as has been published previously for other biomarkers (30 (link), 31 (link)).
+ Open protocol
+ Expand
2

Serum AMH, FSH, and E2 Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples obtained by venipuncture were centrifuged, within 30 minutes from the collection, for 10 min at 3500 rpm, 4°C. Aliquots of each serum were frozen at −80°C and stored for subsequent assays of AMH, FSH and E2. To measure serum AMH levels, AMH-Gen II ELISA assay kit (Beckman Coulter) was used. The lowest detection limit of AMH is 0.08 ng/mL and the intra and interassay coefficients of variation below 3.4% and 4.0% respectively. The ECLIA method used to measure the levels of serum FSH and E2 by COBAS e411 auto-analyser (Roche Diagnostics). The lowest detection limit for FSH is 0.100 IU/L, with the intra- and interassay coefficients of variation below 2.6% and 3.5% respectively. The lowest detection limit for E2 is 18.4 pmol/L, with the intra- and interassay coefficients of variation of 2% and 3%, respectively.
Giving the poor reliability of the FSH value in presence of Estradiol levels greater than 70 pg/mL, women with basal E2 levels greater than this cut off were asked to come back at the beginning of the subsequent menstrual cycle, and their data were excluded from the analysis.
+ Open protocol
+ Expand
3

Serum AMH level quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum anti-Müllerian hormone (AMH) concentration was determined using the commercially available AMH Gen II ELISA assay kit (Beckman Coulter, California, A79766) according to the manufacturer's instructions. AMH levels were measured for serum samples of 12-month-old WT (n = 6), Asc−/− (n = 6), and Nlrp3−/− mice (n = 6). Serum samples were assayed in duplicates and the absorbance was measured using the CLARIOstar microplate reader (BMG Labtechset, Ortenberg, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!