Three blood pressure (BP) readings were taken at regular intervals in a stable state. The mean of the second and third BPs was measured as the final systolic blood pressure (SBP) and final diastolic blood pressure (DBP). Blood sampling was performed in the morning, after fasting for ≥8 h, by cubital vein puncture using a vacutainer needle with blood drawn into a vacuum tube. FBG was measured by the hexokinase ultraviolet method and analysed with a Hitachi Automatic Analyzer 7600-210 (Hitachi, Marunouchi, Japan) using Pureauto S GLU (Sekisui, Osaka, Japan) reagent. The HbA1c assay was measured by a high-performance liquid chromatography assay analysed with a Tosoh G8 instrument (Tosoh, Shiba, Japan) using HLC-723G8 HbA1c (Tosoh). The insulin measurement was performed using the electrochemiluminescence method and analysed with a Cobas 8000 instrument (Roche, Basel, Switzerland) using Elecys insulin (Roche).
Hlc 723g8 hba1c
The HLC-723G8 HbA1c is a laboratory equipment product from Tosoh. It is used for the measurement of hemoglobin A1c (HbA1c) levels in blood samples. The HLC-723G8 provides quantitative analysis of HbA1c concentrations.
2 protocols using hlc 723g8 hba1c
Asthma Prevalence and Metabolic Factors
Three blood pressure (BP) readings were taken at regular intervals in a stable state. The mean of the second and third BPs was measured as the final systolic blood pressure (SBP) and final diastolic blood pressure (DBP). Blood sampling was performed in the morning, after fasting for ≥8 h, by cubital vein puncture using a vacutainer needle with blood drawn into a vacuum tube. FBG was measured by the hexokinase ultraviolet method and analysed with a Hitachi Automatic Analyzer 7600-210 (Hitachi, Marunouchi, Japan) using Pureauto S GLU (Sekisui, Osaka, Japan) reagent. The HbA1c assay was measured by a high-performance liquid chromatography assay analysed with a Tosoh G8 instrument (Tosoh, Shiba, Japan) using HLC-723G8 HbA1c (Tosoh). The insulin measurement was performed using the electrochemiluminescence method and analysed with a Cobas 8000 instrument (Roche, Basel, Switzerland) using Elecys insulin (Roche).
Measuring Severe Hyperglycemia in Diabetes
with a reagent of HLC-723G8 HbA1c (Tosoh/Japan) by Tosoh G8 (Tosoh/Japan). Patients with
HbA1c levels >9.0% were considered as severely hyperglycemic because if these patients
had complications related to DM, insulin injections would be required rather than oral
medications11 (link), 12 (link)); we set this criterion as the definition of “poorly
controlled”.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!