The largest database of trusted experimental protocols

Immulite 2000 nt probnp

Manufactured by Siemens

The IMMULITE 2000 NT-proBNP is a diagnostic lab equipment designed for the quantitative determination of NT-proBNP (N-terminal pro-brain natriuretic peptide) in human serum and plasma. The core function of this instrument is to perform automated immunoassay testing to measure the levels of NT-proBNP, which is a biomarker used in the assessment of various cardiovascular conditions.

Automatically generated - may contain errors

2 protocols using immulite 2000 nt probnp

1

Cardiac Biomarkers Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma concentrations of cTnI and NT-proBNP were measured by radioimmunoassay (ADVIA Centaur TnI-Ultra Assay, Siemens; IMMULITE 2000 NT-proBNP, Siemens). cTnI was considered positive for values >6 ng/L and significantly elevated at a level >40 ng/L (99th percentile). NT-proBNP was considered positive at a level of >125 pg/ml.
+ Open protocol
+ Expand
2

Evaluation of Cardiovascular Risk Markers in Rheumatoid Arthritis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood was collected after overnight fasting to determine blood cell counts, ESR, serum concentration of CRP, creatinine (Cr), uric acid, glucose, total cholesterol (TC), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C), triglycerides (TG) at the central laboratory of University Hospital. CRP was measured by immunoturbidimetric assay (upper limit 5 mg/l). Concentrations of TC, HDL-C, TG were measured with standard enzymatic technique (BIOMAXIMA); LDL-C was calculated according to Friedewald formula. Atherogenic index (AI) calculated as ratio TC/HDL-C seems to be more appropriate to assess CV risk in RA than individual cholesterol fractions (normal AI: <4.0 in women and <4.5 in men) [19 (link)].
Serum samples were stored at −80o C for further assessment of NT-pro-BNP. Measurement of NT-proBNP concentration was performed using chemiluminescent immunometric assay (IMMULITE 2000 NT-proBNP, Siemens). Reference range according to manufacturer’s guidelines is up to 125 pg/ml in patients <75 years and up to 450 pg/ml in older; analytical sensitivity 10 pg/ml. BNP and NT-proBNP levels ≥100 pg/ml are significantly related to cardiac morbidity and mortality [12 (link)].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!