Ptp 6 6 peltier system

Manufactured by PerkinElmer

The PTP 6+6 Peltier System is a laboratory equipment product designed to provide precise temperature control. The core function of this system is to use Peltier elements to accurately regulate the temperature of samples or reactions, enabling controlled experimentation and analysis.

Automatically generated - may contain errors

2 protocols using ptp 6 6 peltier system

1

Optical and Electrochemical Characterization of Polymers

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 2

Film UV-Vis absorption spectra of polymers from Example 2 were acquired on a Perkin Elmer Lambda 20 UV/VIS Spectrophotometer. All film samples were spin-cast on ITO/ZnO substrates. Solution UV-Vis absorption spectra at elevated temperatures were collected on a Perkin Elmer Lambda 950 UV/VIS/NIR Spectrophotometer. The temperature of the cuvette was controlled with a Perkin Elmer PTP 6+6 Peltier System, which is supplied by a Perkin Elmer PCB 1500 Water Peltier System. Before each measurement, the system was held for at least 10 min at the target temperature to reach thermal equilibrium. A cuvette with a stopper (Sigma Z600628) was used to avoid volatilization during the measurement. The onset of the absorption is used to estimate the polymer bandgap.

Cyclic voltammetry was carried out on a CHI760E electrochemical workstation with three electrodes configuration, using Ag/AgCl as the reference electrode, a Pt plate as the counter electrode, and a glassy carbon as the working electrode. Polymers were drop-cast onto the electrode from DCB solutions to form thin films. 0.1 mol L−1 tetrabutylammonium hexafluorophosphate in anhydrous acetonitrile was used as the supporting electrolyte. Potentials were referenced to the ferrocenium/ferrocene couple by using ferrocene as external standards in acetonitrile solutions. The scan rate is 0.1 V s−1.

+ Open protocol
+ Expand
2

Temperature-Dependent UV-Vis Absorption Spectroscopy

Check if the same lab product or an alternative is used in the 5 most similar protocols
Film ultraviolet–visible absorption spectra were acquired on a Perkin Elmer Lambda 20 ultraviolet/visible Spectrophotometer. All film samples were spin-cast on ITO/ZnO substrates. Solution ultraviolet–visible absorption spectra at elevated temperatures were collected on a Perkin Elmer Lambda 950 ultraviolet/visible/NIR Spectrophotometer. The temperature of the cuvette was controlled with a Perkin Elmer PTP 6+6 Peltier System, which is supplied by a Perkin Elmer PCB 1,500 Water Peltier System. Before each measurement, the system was held for at least 10 min at the target temperature to reach thermal equilibrium. A cuvette with a stopper (Sigma Z600628) was used to avoid volatilization during the measurement.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!