The largest database of trusted experimental protocols

Acl top hemostasis testing system

Manufactured by Werfen
Sourced in United States

The ACL TOP® hemostasis testing system is a laboratory instrument designed for performing coagulation assays. It offers automated processing of samples and reagents to analyze various parameters related to blood clotting and hemostasis.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using acl top hemostasis testing system

1

Automated Clot Lysis Assay for Tenecteplase

Check if the same lab product or an alternative is used in the 5 most similar protocols
Clot lysis was determined by an automated ACL TOP® hemostasis testing system (Instrumentation Laboratory, Bedford, MA, USA), in which the lysing effect is measured as a decrease of turbidity. Briefly, standard (5 concentrations, 400–1200 ng/ml) or multiple dilutions of tenecteplase were pipetted into sample cups (20 μl), thrombin solution (20 μl) was added and then the reaction was started by addition of a freshly mixed plasminogen/fibrinogen solution (200 μl) at 37°C. The measured lysis time was then plotted against tenecteplase concentration on a double-logarithmic scale. Enzyme activity was expressed as % of that of reference standard as assessed within the same experiment.
+ Open protocol
+ Expand
2

Dabigatran Concentration Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
DC at the trough and peak times was calculated using HemosIL® direct thrombin inhibitor assay (Instrumentation Laboratory, Bedford, MA, USA). This assay is a dilute thrombin time test, which is based on the reaction between dabigatran and exogenous thrombin added to the diluted patient plasma. The associated clotting time was measured using the ACL TOP hemostasis testing system (Instrumentation Laboratory), and then the concentration of dabigatran was estimated from the reference curve of the known plasma standard of dabigatran using HemosIL® dabigatran calibrators (Instrumentation Laboratory). The trough or peak ΔDC ratio was defined as the trough or peak DC in the period without PPI minus the corresponding DC in the period with PPI divided by the trough or peak DC in the period with PPI. Trough and peak aPTTs were measured using HemosIL® APTT-SP (Instrumentation Laboratory).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!