Dual lc 20ad solvent delivery system

Manufactured by Shimadzu

The Dual LC-20AD solvent delivery system is a core component of Shimadzu's liquid chromatography instrumentation. It features two independent solvent delivery pumps that can be operated simultaneously or independently to provide precise and reliable solvent delivery for a variety of analytical applications.

Automatically generated - may contain errors

4 protocols using dual lc 20ad solvent delivery system

1

Analytical Techniques for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
TLC was done on silica gel 60 GF254 plates (Merck; 0.25 mm) and sprayed with the staining reagent Ce(SO4)2. Column chromatography (CC) was performed using silica gel (Kieselgel 60, 70–230 mesh ASTM; Merck). Preparative TLC was conducted on square glass plates (Kieselgel F254 ; Merck). HPLC was carried out using a Shimadzu dual LC-20AD solvent delivery system with a Shimadzu SPD-M20A UV/vis photodiode array detector. 1H and 13C NMR spectra were measured in acetone-d6 (TMS as an internal standard), on an Agilent 500 MHz spectrophotometer (Agilent Technologies) or Bruker Avance III 700 MHz spectrometer equipped with a 5 mm 13C NMR cryogenic probe or a Bruker 500 MHz spectrometer. HRESI-MS was carried out in positive ion mode on a 6230 TOF mass spectrometer (Agilent Technologies). IR spectra were produced using a Nicolet IR100 FT-IR spectrophotometer (Thermo Fisher Scientific). UV spectra were produced using an Eppendorf BioSpectrometer® kinetic instrument.
+ Open protocol
+ Expand
2

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a Jasco P1010 polarimeter. UV spectra were obtained on an Eppendorf BioSpectrometer. Circular Dichroism (CD) spectra were recorded on a Jasco J-815 Circular Dichroism spectropolarimeter. The 1H and 13C NMR spectra were measured on a Bruker Avance III 700 MHz spectrometers (Bruker Bio Spin AG, Industriestrasse 26, Fällanden, Switzerland). Low-resolution mass spectra were obtained from an AB SCIEX 3200 QTRAP mass spectrometer and high-resolution ESI mass spectra were obtained using an Agilent 1260 HPLC upstream of an Agilent 6545 Q-ToF. HPLC was performed using a Shimadzu dual LC-20AD solvent delivery system with a Shimadzu SPD-M20A UV/vis photodiode array detector. Column chromatography was performed over silica gel (SiO2, 200–300 mesh).
+ Open protocol
+ Expand
3

Analytical Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a Jasco P1010 polarimeter. The 1H and 13C NMR spectra were measured on a Bruker 500 MHz or a Bruker Avance III 700 MHz spectrometers (Bruker Bio Spin AG). Low-resolution mass spectra were obtained from an AB SCIEX 3200 QTRAP mass spectrometer and high-resolution ESI mass spectra were obtained using an Agilent 1260 HPLC upstream of an Agilent 6545 Q-ToF. HPLC was performed using a Shimadzu dual LC-20AD solvent delivery system with a Shimadzu SPD-M20A UV/vis photodiode array detector. Column chromatography was performed over silica gel (SiO2, 200–300 mesh). Thin-layer chromatography was performed on aluminum sheets with silica gel 60 F254 (EMD chemicals Inc.).
+ Open protocol
+ Expand
4

Isolation and Characterization of Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All of the solvents, reagents, and chemicals used in this study were purchased from Aldrich Chemical (Saint Louis, MO, USA) and Merck AG (Saint Louis, MO, USA). Thin-layer chromatography (TLC) was conducted on pre-coated silica gel 60 GF254 plates (Merck, Darmstadt, Germany) with an absorbent thickness of 0.25 mm sprayed with Ce(SO4)2 solution for spot visualization. Preparative TLC was performed on square glass plates with a side length of 0.2 m coated with 0.5 mm Kieselgel F254 (Merck), which were air-dried and used without prior activation. Column chromatography (CC) was performed on silica gel (Kieselgel 60, 70–230 mesh ASTM; Merck). HPLC was performed using a Shimadzu dual LC-20AD solvent delivery system with a Shimadzu SPD-M20A UV/vis photodiode array detector. Nuclear magnetic resonance (1H NMR and 13C NMR) spectra were recorded in acetone-d6 or CDCl3 with tetramethylsilane as an internal standard on a Bruker Avance III 700 MHz spectrometer equipped with a 5 mm 13C cryogenic probe or a Bruker 500 MHz spectrometer. High-resolution ESI mass spectrometry was performed in positive ion mode on a 6230 TOF mass spectrometer (Agilent Technologies, Santa Clara, CA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!