The largest database of trusted experimental protocols

Gelfoam 12 7 mm

Manufactured by Pfizer

Gelfoam 12–7 mm is a gelatin-based absorbable hemostatic sponge. It is designed to provide temporary control of bleeding.

Automatically generated - may contain errors

2 protocols using gelfoam 12 7 mm

1

Corneal Tracer Application via Iontophoresis

Check if the same lab product or an alternative is used in the 5 most similar protocols
At 72 h prior to LGE or sham surgery tracers were applied to the cornea, including FluoroGold (FG, 3% in Na+Cl; Fluorochrome, Denver, CO, USA), Fast Blue (FB, 5% in Na+Cl; PolySciences, Warrington, PA), FM-143x (FM, 5% in NaCl, ThermoFisher Scientific, Waltham, MA, USA) and 1,1′-dioctadecyl-3,3,3′3,3′ -tetramethyl-indocarbocyanine perchlorate (DiI, 5% in 20% DMSO in H2O, ThermoFisher Scientific, Waltham, MA, USA). Under isoflurane anesthesia, a DC current (7 μA for 10 min) (Kumar et al., 2017 ) was passed between a copper wire in a capillary tube filled with either a single tracer or a combination of two (FG/FM143x, FB/FM143x, FG/DiI) and a copper cathode placed in the tail (Fig. 1A). An absorbent gelatin sponge (Gelfoam 12–7 mm; Pfizer Pharmaceuticals, New York, NY) was cut, inserted into the capillary tube, and placed in contact with both the cornea and the tracer solution within the capillary tube, thus allowing the current to pass through to the cornea (Cassagne et al., 2016 (link)). In preliminary studies, iontophoresis did not produce signs of epithelial damage as evidenced by an absence of corneal fluorescein staining.
+ Open protocol
+ Expand
2

Jag1-Enhanced Bone Regeneration

Check if the same lab product or an alternative is used in the 5 most similar protocols
US FDA-approved absorbable gelatin sponges (Pfizer Gelfoam 12–7 mm), 2 mm thick and cut using a 1.5 mm biopsy punch, were incubated for 45 min prior to the start of surgeries in 15 μL of either PBS (vehicle) or 400 μg/mL recombinant rat Jag1 (R&D Systems AF599) in PBS. The surgical sites were accessed by craniolateral incision and blunt dissection between the Rectus femoris and Vastus lateralis muscles. Femurs were elevated using forceps and through-and-through window defects were created in the distal metaphysis 5 mm proximal to the femoral trochleae using a Dremel 8100 with a 0.75 mm drill bit. Defects were plugged with collagen grafts from each group (left side vehicle, right side Jag1) and incisions were sutured shut. Ten animals received bilateral femoral window defects, with n = 5 analyzed at day 10 and n = 5 analyzed at day 20.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!