Agilent masshunter profinder

Manufactured by Agilent Technologies
Sourced in United States

Agilent MassHunter Profinder is a software application designed for data processing and analysis in mass spectrometry. It provides tools for accurate mass feature extraction, compound identification, and data visualization.

Automatically generated - may contain errors

Lab products found in correlation

4 protocols using agilent masshunter profinder

1

Comprehensive Metabolomic Data Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The GC-MS data were processed using an in-house MATLAB script, R2016a (The MathWorks, Inc., Natick, MA, USA). The LC-MS data were processed using Agilent Masshunter Profinder version B.08.00 (Agilent Technologies Inc., Santa Clara, CA, USA). Putative metabolites were extracted using unique mass channels, retention indices (GC-MS data), MS-MS spectra (LC-MS dat) and matched to our in-house mass spectral library at the Swedish Metabolomics Centre (www.swedishmetabolomicscentre.se, 10 October 2021). Labelled internal standards were used for alignment and normalization. Extensive filtering was performed to remove noise and entities with poor quality (e.g., suffering from peak broadening, ion suppression, or non-Gaussian peaks), and only unique spectral profiles with a relative standard deviation (RSD) < 40% calculated from QC samples were included in sample comparison modelling. Criteria set by the Human Metabolome Database (www.HMDB.ca, 15 August 2021) were used to assign extracted components to different compound classes (e.g., amino acids and derivatives, BCAAs, carbohydrates, lipid subtypes, or no class). All lipids were annotated according to standard lipid nomenclature set by Lipid Maps Lipidomics Gateway (lipidmaps.org).
+ Open protocol
+ Expand
2

Lipid Identification via LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
The peak areas of ISs were calculated using the Agilent MassHunter ProFinder version B.08.00 (Agilent Technologies Inc., Santa Clara, CA, USA). The targeted data processing on all samples was performed on the pooled samples using the Batch Targeted Feature Extraction algorithm with the Agilent software MassHunter ProFinder. In-house database with exact mass (m/z) and experimental retention (RT) times of the lipids were used for compound identification.
+ Open protocol
+ Expand
3

Lipid Profiling of Mycobacterium tuberculosis Infection

Check if the same lab product or an alternative is used in the 5 most similar protocols
To illustrate the benefit of counting with an extensive lipid database of a particular biological matrix, we investigated the lipid alterations induced by the Mtb infection at two different time points (4 weeks, Mtb+4w and 12 weeks, Mtb+12w) post-infection. The previously obtained database, including molecular formulas, mass, and RT information, was imported into the Agilent MassHunter Profinder software (B.10.0.2, Agilent Technologies, Santa Clara, CA, USA) using the Batch Targeted Feature Extraction mode to perform the feature extraction and time alignment. Features were built as the sum of coeluting ions that are related by charge-state envelope, isotopologue pattern, and/or the presence of different adducts and dimers in the analyzed samples. To detect coeluting adducts of the same feature, the following adducts were selected: [M + H]+, [M+Na]+, [M + K]+, [M + NH4]+ and [M + C2H6N2 + H]+ in LC-ESI(+)-MS; [M-H], [M+Cl], [M + CH3COOH-H], and [M + CH3COONa-H] in LC-ESI(-)-MS.
+ Open protocol
+ Expand
4

UPLC-Q-TOF Mass Spectrometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Positive ion mode was used on an Agilent Q-TOF G6545B mass spectrometer (Agilent Technologies). The ESI source's characteristics were tuned as follows: capillary voltage, 3500 V; nozzle voltage, 1000 V; fragmentor voltage, 100 V; gas temperature, 320 °C; gas flow, 8 L/min; nebulizer pressure, 35 psi; sheath gas temperature, 350 °C; sheath gas flow rate, 11 L/min. Real-time modifications to the measured masses were made using the internal references Purine and HP-0921. In the positive ion mode, the reference masses were m/z 121.0508 and 922.0097. For both MS and MS/MS studies, the mass spectrometer's complete scan range was m/z 100–1700. The program Agilent MassHunter Profinder (version 10.0, Agilent, USA) was utilized to handle the raw data from the UPLC Q-TOF MS analysis. MPP software (version 15.1, Agilent) was used to conduct principal component analysis (PCA) of the separated metabolites (Appendix Text A3). Every experiment was run three times.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.