The largest database of trusted experimental protocols

M chloroperbenzoic acid

Manufactured by Merck Group
Sourced in United States

M-chloroperbenzoic acid is a chemical compound used as a laboratory reagent. It has the chemical formula C₇H₅ClO₃ and is a white crystalline solid. The compound serves as an oxidizing agent in various chemical reactions. Further details on its specific applications are not included to maintain an unbiased and factual approach.

Automatically generated - may contain errors

5 protocols using m chloroperbenzoic acid

1

Synthesis of Unsaturated Esters from Piperitols

Check if the same lab product or an alternative is used in the 5 most similar protocols

m-Chloroperbenzoic acid was purchased from Sigma-Aldrich (Poznań, Poland). Racemic and optically active γ,δ-unsaturated esters (2a-c and 8a-c) were synthesized from the corresponding cis- and trans-piperitols as described earlier [13 ].
+ Open protocol
+ Expand
2

Synthesis of 5-Acetoxy-1-Cyclooctene via ROMP

Check if the same lab product or an alternative is used in the 5 most similar protocols
All manipulations involving air- and moisture-sensitive compounds were carried out in oven-dried glassware using dry solvents and standard Schlenk and vacuum-line techniques under an argon atmosphere. The 5-acetoxy-1-cyclooctene (COAc) monomer was synthesized according to the procedure described in [26 (link)]. Norbornene and cis, cis-1,5-cyclooctadiene (Sigma-Aldrich, St. Louis, MO, USA) were dried over sodium and stored under argon. Norbornene was used as a 4.6 M solution in dry chloroform. Grubbs’ catalysts of the 1st (Cl2(PCy3)2Ru=CHPh, G1) and 2nd (Cl2(PCy3)ImesRu=CHPh, G2) generations (Sigma-Aldrich, St. Louis, MO, USA) were used without purification in the form of 0.002–0.022 M solutions in dry chloroform. m-Chloroperbenzoic acid, p-toluenesulfonyl hydrazide, and inhibitor of oxidation 2,2′-methylene-bis (6-tert-butyl-4-methylphenol) (Sigma-Aldrich, St. Louis, MO, USA) were used as supplied. Other reagents and solvents were purified using common procedures.
+ Open protocol
+ Expand
3

Spectroscopic Analysis of Benzothiazine Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents and reagents were
obtained from commercial sources and used without further purification.
UV–vis absorption spectra were registered at room temperature
on a V-560 JASCO spectrophotometer using calibrated 2 mL quartz cuvettes.
LC–MS analyses were performed on an HPLC instrument Agilent
1100 Series MSD equipped with a UV–vis detector and an electrospray
ionization source in positive ion mode (ESI+). Detection
wavelength was set at 254 nm. The spray voltage was set at 3.5 kV.
Nitrogen was employed as both drying and nebulizer gas. Mass spectra
were registered with the cone and fragmentator voltage set at 4 kV
and 80 V, respectively. An octyl column (15 cm × 4.6 mm, 3 μm
particle size) was used. An acetonitrile/water gradient was used as
follows: 0–50 min, 50–70% acetonitrile and 50–60
min, 70% acetonitrile. The flow rate was set at of 0.7 mL/min.
2,2-Diphenyl-1-picrylhydrazyl (DPPH) or 4-hydroxy-2,2,6,6-tetramethylpiperidin-1-oxyl
(TEMPO), 2,3-dichloro-5,6-dicyanobenzoquinone, sodium persulfate, m-chloroperbenzoic acid, iron(II) chloride, and chloranil
were purchased from Sigma-Aldrich. 3-Phenyl-1,4-benzothiazine (1) and 3,3′-diphenyl-2,2′-bi(1,4-benzothiazine)
(2) were prepared as previously described.10 (link)
+ Open protocol
+ Expand
4

Aflatoxin Quantification Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Glucose 6-phosphate sodium salt, glucose 6-phosphate dehydrogenase, nicotinamide dinucleotide phosphate (NADP+), ethylenediaminetetraacetic acid (EDTA), bicinchoninic acid solution (sodium carbonate, sodium tartrate, sodium bicarbonate and sodium hydroxide 0.1 N pH 11.25), copper sulphate pentahydrate, formic acid, sucrose, bovine serum albumin, sodium borohydride, m-chloroperbenzoic acid, ethanol (spectrophotometric grade), isopropyl alcohol, 2-(cyclohexylamino) ethane sulfonic acid (CHES), aflatoxin B2a and N,N-dimethylformamide were from Sigma-Aldrich (St. Louis, MO, USA). Aflatoxin B1 was from Fermentek Ltd. (Jerusalem, Israel). Sodium phosphate monobasic monohydrate, sodium phosphate dibasic anhydrous and sodium chloride were from Merck (Darmstadt, Germany). Methanol, acetonitrile and water were all HPLC grade.
+ Open protocol
+ Expand
5

Polymer-Based Emulsifier Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Poly(vinyl alcohol)-(PVA, Mw=30,000-70,000, 87-90% hydrolysed), polyoxyethylene sorbitan monooleate-(Tween 80) and Pluronic F68 emulsifiers; ethanol, acetone, dimethyl sulfoxide (DMSO), sodium azide, 1-ethyl-3(3dimethylaminopropyl) carbodiimide (EDC), Nhydroxysuccinimide (NHS) and 3-(4,5-dimethylthiazol-2-yl)-2,5diphenyltetrazolium bromide (MTT), abs. toluene, tripropylamine, p-toluenesulfonyl hydrazide, xylenes, BHT, 1,4dioxane, TFA, abs. THF, LiAlH 4 , abs. diethyl ether, Nmethylmorpholine N-oxide, OsO 4 , n-hexane, 1,5cyclooctadiene, m-chloroperbenzoic acid, 1,6-heptadiene-4-ol, palladium on carbon, ethyl vinyl ether and fluorescein sodium salt were obtained from Sigma Aldrich, ruthenium catalyst G2 was from Materia Inc. Sorafenib (free base) was purchased from LC Laboratories (US). Cyanine 5 amine was the product of Lumiprobe Gmbh (Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!