The largest database of trusted experimental protocols

3 protocols using agilent 6530 accurate mass spectrometer

1

Anti-inflammatory Activity of D. benenica

Check if the same lab product or an alternative is used in the 5 most similar protocols
Diclofenac, carrageenan, and solvents such as n-hexane, chloroform, acetone, ethyl acetate, and methanol were obtained from Sigma-Aldrich (St Louis, MO, USA). Mueller-Hinton Broth was purchased from Thermo Fisher Scientific (Massachusetts, USA). silica gel (60 N, spherical, neutral, 40-50 μm) was obtained from Kanto Chemical Co., Inc. (Tokyo, Japan). Plethysmometer was purchased from Panlab, Havard Apparatus. Infrared spectra were recorded on an IR Prestige-21 spectrometer (Shimadzu, Kyoto, Japan). NMR spectra were recorded using a Bruker Avance 500 spectrometer (Bruker, MA, USA), with TMS as an internal reference. HRESIMS data were measured on an Agilent 6530 Accurate-Mass spectrometer (Agilent, CA, USA). Analytical TLC was performed on precoated silica gel 60F254 and RP-18 F254 plates (0.25 or 0.50 mm thickness, Merck KGaA, Darmstadt, Germany). Spots were detected under UV radiation (254 nm and 365 nm) and by spraying the plates with 10% sulfuric acid followed by heating with a heat gun.
D. benenica Q.B.Nguyen & Škorničk was collected in January 2020 at Quang Nam province and identified by Hue University of Agriculture and Forestry. A voucher specimen (DB1) was deposited in the Faculty of Chemistry at the Hue University of Education.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Ag(I)-NHC Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
All these experiments were performed using normal Schlenk techniques in freshly dried solvents under in air or nitrogen atmosphere.
Synthesis of Ag(I)–NHC complex reactions were performed in the absence of light. Ag2O and solvents used in this work were purchased from Sigma-Aldrich. The compounds' elements were examined using the ElementarVario EL III Carlo Erba 1108 instrument. The melting points of the compounds were calculated using a Stuart automated melting point apparatus (SMP-40). The 1H and 13C{1H} NMR spectra were obtained using Bruker Avance III HD 300 and 400 MHz NMR spectrometers. The J values for coupling constants are displayed in hertz. For the HRMS study, an Agilent 6530 Accurate-Mass spectrometer was used. A PerkinElmer Spectrum 100 GladiATR FT/IR spectrometer was used to record FTIR spectrum.
+ Open protocol
+ Expand
3

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
A JASCO P-2000 polarimeter (Hachioji, Tokyo, Japan) was used to record optical rotation. UV spectra were measured using a Shimadzu UV-1800 spectrophotometer (Shimadzu, Kyoto, Japan). Circular dichroism spectra were studied with a Chirascan CD spectrometer (Applied Photophysics Ltd., Surrey, United Kingdom). A Bruker Avance 500 spectrometer (Bruker, MA, USA) was exploited for investigating NMR spectra and TMS as an internal reference. HRESIMS data were performed using an Agilent 6530 Accurate-Mass spectrometer (Agilent, CA, USA). The column chromatography studies were conducted with YMC RP-18 (Fuji Silysia Chemical Ltd, Kasugai, Aichi, Japan), Cosmosil 75C18-OPN (Nacalai Tesque Inc., Kyoto, Japan), silica gel (40–50 µm, Kanto Chemical Co., Tokyo, Japan), Diaion HP-20 (Mitsubishi Chem. Co., Tokyo, Japan) and Sephadex LH-20 (Dowex 50WX2-100, Sigma–Aldrich, USA). Pre-coated silica gel 60F254 and RP-18 F254 plates (0.25 or 0.50 mm thickness, Merck, Germany) were exploited to investigate analytical TLC. Preparative HPLC with a DAD detector applied was Agilent 1260 Infinity II system (Agilent, CA, USA) and using a Zorbax SB–C18 column (5 µm particle size, 9.4 × 250 mm).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!