The largest database of trusted experimental protocols

Tracegold tg waxms a column

Manufactured by Thermo Fisher Scientific
Sourced in United States

The TraceGOLD™ TG-WaxMS A column is a gas chromatography column designed for the analysis of a wide range of compounds. It features a stationary phase that is optimized for the separation of polar compounds.

Automatically generated - may contain errors

2 protocols using tracegold tg waxms a column

1

Histological and Metabolomic Analysis of Intestinal Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Duodenal samples were fixed in fresh 4% (v/v) buffered formaldehyde, dehydrated, and embedded in paraffin as previously described38 (link). Serial sections (5 µm) were deparaffinized in xylene and stained with hematoxylin and eosin before goblet cell number and villi surface area examination under light microscopy using EPIX XCAP software (Standard version, Olympus, Waltham, MA, USA). Cecal samples were homogenized in HCl (2 ml, 3%, 1 M), centrifuged and combined with ethyl acetate (100 µL) and acetic acid-d4 (1 µg/mL) before collecting the organic phase to determine short chain fatty acid (SCFA) composition. Samples were quantified via GC-MS using a TRACE™ 1310 gas chromatograph (Thermo Fisher Scientific, Waltham, MA, USA) and a TraceGOLD™ TG-WaxMS A column (Thermo Fisher Scientific, Waltham, MA, USA).
+ Open protocol
+ Expand
2

Cecal Short-Chain Fatty Acid Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
As was previously described [28 (link)], cecal samples were homogenized in HCl (2 mL, 3%, 1 M), centrifuged and combined with ethyl acetate (100 µL) and acetic acid-d4 (1 µg/mL) before collecting the organic phase to determine short-chain fatty acid (SCFA) composition. Samples were quantified via GC-MS using a TRACE™ 1310 gas chromatograph (Thermo Fisher Scientific, Waltham, MA, USA) and a TraceGOLD™ TG-WaxMS A column (Thermo Fisher Scientific, Waltham, MA, USA). The pH of cecum content was determined using an Oakton® model 700 digital pH meter (Oakton Instruments, Vermon Hills, IL, USA). Before testing, the potentiometer was calibrated with pH buffers at 1.68, 4.01, 7.00, 10.01, and 12.45 according to the manufacturer’s recommendations.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!