The largest database of trusted experimental protocols

Metworks version 1.3

Manufactured by Thermo Fisher Scientific
Sourced in United States

MetWorks (Version 1.3) is a software application developed by Thermo Fisher Scientific for data analysis and management in laboratory environments. The core function of MetWorks is to provide a comprehensive platform for organizing, processing, and interpreting analytical data collected from various laboratory instruments and techniques.

Automatically generated - may contain errors

2 protocols using metworks version 1.3

1

High-Resolution Mass Spectrometry Analysis of Daidzein Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Thermo Xcalibur 2.1 workstation (Thermo Scientific) was adopted for acquiring and processing HR-ESI-MS1 and MSn data. To obtain as many product ions of daidzein metabolites as possible, the peaks detected with intensity over 10,000 for negative ion mode and 50,000 for positive ion mode were selected for further structural characterization. The chemical formula for all parent ions were calculated from accurate mass using a formula predictor with the parameters set as followings: C [6–35], H [5–50], O [0–15], S [0–5], N [0–5], and ring double bond (RDB) equivalent value [0–15]. Meanwhile, MetWorks (Version 1.3) and Mass Frontier (Version 8.0) software (Thermo Scientific, Waltham, MA, USA) were utilized for mass fragmentation behaviors analysis, structural elucidation, and chromatographic peaks extraction.
+ Open protocol
+ Expand
2

High-Resolution Mass Spectrometry Analysis of Phillyrin Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Thermo Xcalibur 2.1 workstation (Thermo Scientific, Bremen, Germany) was utilized to acquire and process HR-ESI-MS1 and MSn data. Based on the established screening templates of metabolites, by searching the metabolites with specific molecular weight to compare the high-resolution extracted ion chromatograms of the Control Group and the Drug Group, the metabolites related to phillyrin were selected. To obtain as many phillyrin metabolite ions as possible, the peaks detected with intensity over 10,000 for negative ion mode and 50,000 for positive ion mode were selected for further structural characterization. Based on the exact mass of the metabolite and the set elemental composition, the formula predictor could accurately calculate the chemical formula of all parent ions. The type and number of atoms were set as follows: C [0–40], H [0–60], O [0–25], S [0–2], N [0–5], and ring double bond (RDB) equivalent value [0–15]. At the same time, MetWorks (Version 1.3) and Mass Frontier (Version 8.0) software (Thermo Scientific, Waltham, MA, USA) were used as auxiliary tools for mass fragmentation behaviors analysis and structural identification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!