The largest database of trusted experimental protocols

Thermo q exactive ms focus

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Thermo Q-Exactive MS focus is a high-resolution, accurate-mass (HRAM) mass spectrometer. It is designed to provide high-quality data for a wide range of analytical applications.

Automatically generated - may contain errors

4 protocols using thermo q exactive ms focus

1

UHPLC-MS Analysis of Ethanolic Extract

Check if the same lab product or an alternative is used in the 5 most similar protocols
A UHPLC-high-resolution MS machine (Thermo Dionex Ultimate 3000 system with PDA detector controlled by Chromeleon 7.2 software hyphenated with a Thermo Q-Exactive MS focus, (Thermo Fisher Scientific, Bremen Germany was used to determine the compounds in the extract. For the analysis, 5 mg of the ethanolic extract was dissolved in 2 mL of methanol, filtered through a 200 µm polytetrafluoroethylene (PTFE) filter, and 10 µL was injected in the instrument [58 (link)].
+ Open protocol
+ Expand
2

UHPLC-HRMS Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
An UHPLC-high-resolution MS machine Thermo Dionex Ultimate 3000 system with PDA detector controlled by Chromeleon 7.3 software (Thermo Fisher Scientific, Waltham, MA, USA) hyphenated with a Thermo Q-Exactive MS focus (Thermo, Bremen, Germany) was used [16 (link)].
+ Open protocol
+ Expand
3

UHPLC-MS Analysis of Resin Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
An UHPLC-high-resolution MS machine (Thermo Dionex Ultimate 3000 system with PDA detector controlled by Chromeleon 7.3 software (Thermo Fisher Scientific, Waltham, MA, USA) hyphenated with a Thermo Q-Exactive MS focus (Thermo, Bremen, Germany) was used [16 (link)]. For the analysis, 5 mg of the resin was dissolved in 2 mL of methanol, filtered through a 200-µm PTFE (polytetrafluoroethylene)filter, and 10 µL was injected in the instrument, considering all specifications as reported [29 (link)].
+ Open protocol
+ Expand
4

UHPLC-HRMS Analysis of Lyophilized Material

Check if the same lab product or an alternative is used in the 5 most similar protocols
An UHPLC-high-resolution MS machine Thermo Dionex Ultimate 3000 system with PDA detector controlled by Chromeleon 7.2 software (Thermo Fisher Scientific, Waltham, MA, USA) hyphenated with a Thermo Q-Exactive MS focus (Thermo, Bremen, Germany) was used [22 (link)]. For the analysis, 5 mg of the lyophilized material was dissolved in 2 mL of methanol, filtered through a 200-µm PTFE (polytetrafluoroethylene) filter, and 10 µL was injected in the instrument, considering all specifications as reported [22 (link),23 (link)].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!