12 protocols using inosine 15n4

1

LC-MS Analysis of Stool Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC-MS samples were prepared from stool homogenates (30 µL) via protein precipitation with the addition of four volumes of 80% methanol containing inosine-15N4, thymine-d4 and glycocholate-d4 internal standards (Cambridge Isotope Laboratories; Andover, MA). The samples were centrifuged (10 min, 9,000 x g, 4°C) and the supernatants were injected directly onto a 150 x 2.0 mm Luna NH2 column (Phenomenex; Torrance, CA). The column was eluted at a flow rate of 400 µL/min with initial conditions of 10% mobile phase A (20 mM ammonium acetate and 20 mM ammonium hydroxide in water) and 90% mobile phase B (10 mM ammonium hydroxide in 75:25 v/v acetonitrile/methanol) followed by a 10 min linear gradient to 100% mobile phase A. MS analyses were carried out using electrospray ionization in the negative ion mode using full scan analysis over m/z 60-750 at 70,000 resolution and 3 Hz data acquisition rate. Additional MS settings were: ion spray voltage, -3.0 kV; capillary temperature, 350°C; probe heater temperature, 325 °C; sheath gas, 55; auxiliary gas, 10; and S-lens RF level 40.
+ Open protocol
+ Expand
2

Quantitative LC-MS Analysis of Glutathione

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reduced and oxidized glutathione were profiled in negative ionization mode by liquid chromatography tandem mass spectrometry (LC-MS) methods as described previously38 (link). Data were acquired using an ACQUITY UPLC (Waters Corp, Milford MA) coupled to a 5500 QTRAP triple quadrupole mass spectrometer (AB SCIEX, Framingham MA). Tissue homogenates (30 μL) were extracted using 120 μL of 80% methanol containing 0.05 ng/μL inosine-15N4, 0.05 ng/μL thymine-d4, and 0.1 ng/μL glycocholate-d4 as internal standards (Cambridge Isotope Laboratories, Inc., Tewksbury MA). The samples were centrifuged (10 min, 9,000 × g, 4ºC) and the supernatants (10 μL) were injected directly onto a 150 × 2.0 mm Luna NH2 column (Phenomenex, Torrance CA). The column was eluted at a flow rate of 400 μL/min with initial conditions of 10% mobile phase A (20 mM ammonium acetate and 20 mM ammonium hydroxide (Sigma-Aldrich) in water (VWR)) and 90% mobile phase B (10 mM ammonium hydroxide in 75:25 v/v acetonitrile/methanol (VWR)) followed by a 10 min linear gradient to 100% mobile phase A. The ion spray voltage was −4.5 kV and the source temperature was 500°C. Raw data were processed using MultiQuant 2.1 software (AB SCIEX, Framingham MA) for automated peak integration. LC-MS data were processed and visually inspected using TraceFinder 3.1 software (Thermo Fisher Scientific; Waltham, MA).
+ Open protocol
+ Expand
3

Metabolite Profiling Sample Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sample preparation for metabolite profiling was performed as previously described45 (link). Briefly, tissues were homogenized in 80% methanol containing inosine-15N4, thymine-d4 and glycocholate-d4 internal standards (Cambridge Isotope Laboratories; Andover, MA) at a 4:1 volume to wet weight ratio and centrifuged. Liver or epididymal white fat EF was extracted by centrigation in a 20 μm nylon mesh filter (EMD Millipore; Burlington, MA) as described previously42 (link),43 (link) and were extracted by adding extraction buffer at a ratio of 1:20 extracellular fluid to buffer. For plasma collection, blood was taken via cheek bleed from mice, collected into a heparin column (Becton Dickson; Franklin Lakes, NJ), centrifuged (10 min, max speed, 4°C), and subsequently snap-frozen. Metabolites were extracted from plasma by adding extraction buffer in a 1:4 ratio plasma to extraction buffer.
+ Open protocol
+ Expand
4

Stool Metabolome Analysis by LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC­MS samples were prepared from stool homogenates (30 μL) via protein precipitation with the addition of four volumes of 80% methanol containing inosine­15N4, thymine­d4 and glycocholate­d4 internal standards (Cambridge Isotope Laboratories; Andover, MA). The samples were centrifuged (10 min, 9,000 x g, 4°C) and the supernatants were injected directly onto a 150 × 2.0 mm Luna NH2 column (Phenomenex; Torrance, CA). The column was eluted at a flow rate of 400 μL/min with initial conditions of 10% mobile phase A (20 mM ammonium acetate and 20 mM ammonium hydroxide in water) and 90% mobile phase B (10 mM ammonium hydroxide in 75:25 v/v acetonitrile/methanol) followed by a 10 min linear gradient to 100% mobile phase A. MS analyses were carried out using electrospray ionization in the negative ion mode using full scan analysis over m/z 60­750 at 70,000 resolution and 3 Hz data acquisition rate. Additional MS settings were: ion spray voltage, ­3.0 kV; capillary temperature, 350°C; probe heater temperature, 325 °C; sheath gas, 55; auxiliary gas, 10; and S­lens RF level 40.
+ Open protocol
+ Expand
5

Stool Metabolite Extraction for LC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC–MS samples were prepared from stool ethanol extracts (30 μl) with the addition of four volumes of 80% methanol containing inosine-15N4, thymine-d4 and glycocholate-d4 internal standards (Cambridge Isotope Laboratories). The samples were centrifuged (10 min, 9000 g, 4 °C) and the supernatants were injected directly onto a 150 × 2.0-mm Luna NH2 column (Phenomenex). The column was eluted at a flow rate of 400 μl/min with initial conditions of 10% mobile phase A (20 mM ammonium acetate and 20 mM ammonium hydroxide in water) and 90% mobile phase B (10 mM ammonium hydroxide in 75:25 v/v acetonitrile/methanol) followed by a 10-min linear gradient to 100% mobile phase A. MS analyses were carried out using electrospray ionization in the negative ion mode using full scan analysis over m/z 60–750 at 70,000 resolution and 3 Hz data acquisition rate. Additional MS settings are: ion spray voltage, –3.0 kV; capillary temperature, 350 °C; probe heater temperature, 325 °C; sheath gas, 55; auxiliary gas, 10; and S-lens RF level 40.
+ Open protocol
+ Expand
6

Quantitative LC-MS Analysis of Glutathione

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reduced and oxidized glutathione were profiled in negative ionization mode by liquid chromatography tandem mass spectrometry (LC-MS) methods as described previously38 (link). Data were acquired using an ACQUITY UPLC (Waters Corp, Milford MA) coupled to a 5500 QTRAP triple quadrupole mass spectrometer (AB SCIEX, Framingham MA). Tissue homogenates (30 μL) were extracted using 120 μL of 80% methanol containing 0.05 ng/μL inosine-15N4, 0.05 ng/μL thymine-d4, and 0.1 ng/μL glycocholate-d4 as internal standards (Cambridge Isotope Laboratories, Inc., Tewksbury MA). The samples were centrifuged (10 min, 9,000 × g, 4ºC) and the supernatants (10 μL) were injected directly onto a 150 × 2.0 mm Luna NH2 column (Phenomenex, Torrance CA). The column was eluted at a flow rate of 400 μL/min with initial conditions of 10% mobile phase A (20 mM ammonium acetate and 20 mM ammonium hydroxide (Sigma-Aldrich) in water (VWR)) and 90% mobile phase B (10 mM ammonium hydroxide in 75:25 v/v acetonitrile/methanol (VWR)) followed by a 10 min linear gradient to 100% mobile phase A. The ion spray voltage was −4.5 kV and the source temperature was 500°C. Raw data were processed using MultiQuant 2.1 software (AB SCIEX, Framingham MA) for automated peak integration. LC-MS data were processed and visually inspected using TraceFinder 3.1 software (Thermo Fisher Scientific; Waltham, MA).
+ Open protocol
+ Expand
7

Metabolite Profiling Sample Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sample preparation for metabolite profding was performed as previously described (Xiao et al., 2020 (link)). Briefly, tissues were homogenized in 80% methanol containing inosine-15N4, thymine-d4 and glycocholate-d4 internal standards (Cambridge Isotope Laboratories; Andover, MA) at a 4:1 volume to wet weight ratio and centrifuged.
+ Open protocol
+ Expand
8

Stable Isotopic Labeling of Islet GSH

Check if the same lab product or an alternative is used in the 5 most similar protocols
This method was used for stable isotopic labeling analysis (SITA) of [13C6]-glucose incorporation into GSH. Human donor islets were label led for 24 h in RPMI media containing 5.8 mM [13C6]-glucose at a density of 100 islets/ml media. Islet were extracted by sonication in 80% methanol containing internal standards; inosine-15N4, thymine-d4 and glycocholate-d4 (Cambridge Isotope Laboratories). Extracts were centrifuged at 16,000 RPM 4°C for 20 min, supernatants were collected and loaded onto a Luna-HILIC column through an UltiMate-3000 TPLRS LC, with a mobile phase A (20 mM ammonium acetate and 20 mM ammonium hydroxide dissolved in 5:95 v/v acetonitrile/water) and 90% mobile phase B (10 mM ammonium hydroxide in 75:25 v/v acetonitrile/methanol). Metabolites were separated with a 10 min linear gradient up to 99% mobile phase A. Mass analysis was carried out using a Q-Exactive HF-X mass spectrometer (Thermo Fisher Scientific). Negative modes were used with full scan analysis over m/z 70-750 m/z at 60,000 resolution, 1e6 AGC, and 100 ms maximum ion accumulation time. Additional settings were: ion spray voltage of 3.8 kV; capillary temperature of 350°C; probe heater temperature of 320°C; sheath gas of 50; auxiliary gas of 15; and S-lens RF at level 40.
+ Open protocol
+ Expand
9

Metabolite Extraction and Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Metabolites were extracted using acetonitrile/methanol (75:25; v/v) containing deuterated internal standards (25 μM thymine-d4 [Sigma-Aldrich], 10 μM inosine-15N4 [Cambridge Isotope Laboratories], 10 μM citrulline-d7 [Sigma-Aldrich], 25 μM phenylalanine-d8 [Cambridge Isotope Laboratories], and 10 μM valine-d8 [Sigma-Aldrich]). The samples were separated using a 2.1 × 100 mm 3.5-μm Xbridge amide column (Waters). Mobile phase A was 95:5 (v/v) water/acetonitrile, with 20 mM ammonium acetate and 20 mM ammonium hydroxide (pH 9.5). Mobile phase B was acetonitrile. For amide-negative mode, the chromatography system consisted of a 1260 Infinity autosampler (Agilent) connected to a 1290 Infinity HLPC binary pump system (Agilent). The eluents were detected in negative mode on a coupled 6490 QQQ mass spectrometry equipped with an electrospray ionization source. The settings were as follows: sheath gas temperature, 400 °C; sheath gas flow, 12 L/min; drying gas temperature, 290 °C; drying gas flow, 15 L/min; capillary, 4000 V; nozzle pressure, 30 psi; nozzle voltage, 500 V; and delta EMV, 200 V. Detailed methods have been described previously62 .
+ Open protocol
+ Expand
10

Negative Ion Mode MS of Plasma Metabolites

Check if the same lab product or an alternative is used in the 5 most similar protocols
Negative ion mode MS analysis of polar metabolites. LC–MS samples were prepared from plasma (30 μl) via protein precipitation with the addition of four volumes (120 μl) of 80% methanol containing inosine‐15N4, thymine‐d4, and glycocholate‐d4 internal standards (Cambridge Isotope Laboratories). The samples were centrifuged (10 min, 9000 g, 4°C), and the supernatants were injected directly onto a 150 × 2.0 mm Luna NH2 column (Phenomenex). The column was eluted at a flow rate of 400 μl/min with initial conditions of 10% mobile phase A (20 mM ammonium acetate and 20 mM ammonium hydroxide in water) and 90% mobile phase B (10 mM ammonium hydroxide in 75:25 v/v acetonitrile/methanol) followed by a 10 min linear gradient to 100% mobile phase A. The column temperature was kept at 40°C. MS analyses were carried out using electrospray ionization in the negative ion mode using full scan analysis over m/z 70–750 at 70,000 resolution and 3 Hz data acquisition rate. Additional MS settings are as follows: ion spray voltage, −3.0 kV; capillary temperature, 350°C; probe heater temperature, 325°C; sheath gas, 55; auxiliary gas, 10; and S‐lens RF level 50.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!