Gamma counter wizard 2 3

Manufactured by PerkinElmer
Sourced in United States

The Gamma Counter Wizard 2 3" is a compact and versatile instrument designed for the measurement of gamma radiation. It features a 3-inch well-type sodium iodide (NaI) detector and provides precise and reliable counting capabilities for a wide range of radioisotopes and sample types.

Automatically generated - may contain errors

Lab products found in correlation

4 protocols using gamma counter wizard 2 3

1

Lipophilicity Determination of Gallium Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
For the determination
of the lipophilicity of the gallium complexes, we have delivered the
distribution coefficient between octanol and the PBS buffer of 68Ga-labeled ligands. After dissolution of the investigated
radiolabeled complexes in PBS to a concentration of approximately
9 μM, 50 μL of this solution was added to 450 μL
of PBS and 500 μL of octanol into an Eppendorf tube followed
by vigorous shaking of the two phases for 20 min at 1400 rpm at room
temperature (MS 3 basic vortexer, IKA, Staufen, Germany) followed
by centrifugation for 2 min at 4500 rpm (Eppendorf Centrifuge 5424,
Eppendorf AG, Hamburg, Germany). After that, 200 μL of each
phase was collected and measured in a 2480 automatic Gamma counter
Wizard 2 3″ (PerkinElmer, Waltham, MA, USA). LogD values were
calculated by dividing measured values of octanol by water and logarithmizing
the result. Values > 0 reflect lipophilic compounds; values <
0
reflect hydrophilic compounds (n = 3, six technical
replicates).
+ Open protocol
+ Expand
2

Octanol-PBS Partition Coefficient Determination

Check if the same lab product or an alternative is used in the 5 most similar protocols
Log D was determined by measuring the distribution of each compound between octanol and PBS buffer. For this purpose, radiolabelled compound was dissolved with PBS to 1 mL (~9 µM). Aliquots of 50 µL were added to 450 µL PBS and 500 µL octanol, shaken for 20 min with 1400 rpm at RT (MS 3 basic vortexer, IKA, Staufen, Germany) followed by centrifugation for 2 min at 4500 rpm (Eppendorf Centrifuge 5424, Eppendorf AG, Hamburg, Germany). Hereafter, 200 µL of each phase were collected and measured in a 2480 automatic Gamma counter Wizard 2 3″ (PerkinElmer, Waltham, MA, USA). Log D value was calculated using Excel. (n = 3, six technical replicates)
+ Open protocol
+ Expand
3

LogD Determination of 68Ga-Fluorophore

Check if the same lab product or an alternative is used in the 5 most similar protocols
A 50 µL aliquot of 68Ga-labelled fluorophore conjugate (~ 5 µM) was added to 450 µL PBS + 500 µL n-octanol and mixed for 20 min at 1,400 rpm in a standard vortexer (MS 3, IKA, Staufen, Germany). Subsequently, the mixture was centrifuged for 2 min at 4,500 rpm (Eppendorf Centrifuge 5,424, Hamburg, Germany) and aliquots of 200 µL of each phase were measured in the gamma counter (2,480 automatic Gamma counter Wizard2 3′’, Perkin Elmer, Waltham, MA, USA). LogD was calculated as the ratio of octanol/water phase using Excel. (n = 3, six technical replicates).
+ Open protocol
+ Expand
4

Lipophilicity Determination of Antifungal Siderophores

Check if the same lab product or an alternative is used in the 5 most similar protocols
To determine the lipophilicity of the antifungal siderophore conjugates, the distribution coefficient between octanol and PBS buffer was determined. Radiolabeled compounds were dissolved in PBS to a concentration of approximately 9 µM and 50 µL of this solution was added to 450 μL PBS and 500 μL octanol into an eppendorf tube. The two phases were vigorously shaken for 20 min at 1400 rpm at room temperature (MS 3 basic vortexer, IKA, Staufen, Germany) followed by centrifugation for 2 min at 4500 rpm (Eppendorf Centrifuge 5424, Eppendorf AG, Hamburg, Germany).
Hereafter, 200 µL of each phase was collected and measured in a 2480 automatic Gamma counter Wizard 2 3″ (PerkinElmer, Waltham, MA, USA). LogD values were calculated using Excel by dividing measured values of octanol by PBS and logarithmizing the result. Values > 0 reflect lipophilic, values < 0 reflect hydrophilic compounds (n = 3, six technical replicates).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!