The largest database of trusted experimental protocols

4 protocols using z β ocimene

1

Authentic Standards for Volatile Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Authentic standards of (E)-2-hexenal, p-xylene, α-pinene, β-pinene, trans-isolimonene, β-myrcene, 2-carene, α-phellandrene, 3-carene, α-terpinene, p-cymene, β-phellandrene, (Z)-β-ocimene, (E)-β-ocimene, γ-terpinene, terpinolene, n-nonanal, allo-ocimene, methyl salicylate, β-elemene, (Z)-jasmone, (E)-β-caryophyllene, and α-humulene (>95% purity) were purchased from Sigma-Aldrich (St. Louis, MO, United States). Dichloromethane (99.9% purity) was purchased from Merck (Germany).
+ Open protocol
+ Expand
2

Purchasing Standards for Terpene Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Standards of geranyl pyrophosphate (GPP), farnesyl pyrophosphate (FPP), geraniol, (Z)-β-ocimene, and (E)-β-ocimene were purchased from Sigma-Aldrich (St Louis, MO, USA).
+ Open protocol
+ Expand
3

Characterization of Volatile Compounds in Tea

Check if the same lab product or an alternative is used in the 5 most similar protocols
Geraniol and other volatile compounds in the samples were examined using a combination of SPME and GC/MS (Thermo Scientific TRACE 1300, ISQ 7000, MA, USA). In brief, the tea samples were ground into powder in liquid nitrogen, 0.2 g of each sample was weighed and placed into the sample vial for testing. An internal standard of two μl of ethyl caprate (1 ppm in methyl alcohol) was introduced. The samples were then incubated at 60°C for 1 hour, during which the volatiles were absorbed by the SPME process. GC column: DB-5, 60 m × 0.25 mm, film thickness 0.25 μm (J&W Scientific, USA). Pure helium was used as the carrier gas at a flow rate of 1 mL/min. The GC injector had a split ratio of 10:1. The GC oven condition: maintained at 40°C for 3 min, increased by 5°C/min to 80°C; increased to 160°C at 2°C/min; and then to 240°C at a rate of 10°C/min; held at 240°C for 5 min. Full-scan mode with an m/z range of 300–600 was applied. All compounds were identified by comparison with a mass spectrometry library (NIST) and compounds with known retention times. Geraniol, (Z)-β-ocimene, and (E)-β-ocimene (Sigma-Aldrich Chemie GmbH, Taufkirchen, Germany) were identified using standards.
+ Open protocol
+ Expand
4

GC-MS Analysis of Flavor Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The chemicals used in GC-MS analysis including hexanal, heptanal, benzaldehyde, octanal, nonanal, decanal, 6-methyl-5-hepten-2-one, acetophenone, α-phellandrene, α-pinene, p-cymene, β-citronellene, camphene, sabinene, β-pinene, limonene, 1,8-cineole, (Z)-β-ocimene, (E)-β-ocimene, γ-terpinene, δ-2- carene, (Z)-linalool oxide (furanoid), linalool, α-copaene, α-cedrene, (E)-caryophyllene, α-humulene, (Z)- caryophyllene, skatole, heptanol, octanol, 1-octen-3-ol, nonanol, p-xylene, o-xylene, phenol, benzyl alcohol, m-cresol, p-cresol, indole, and standard n-alkanes solution were purchased from Sigma Aldrich (purity >97%).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!