The largest database of trusted experimental protocols

Easymag automated extractor

Manufactured by bioMérieux
Sourced in United States

The EasyMAG automated extractor is a laboratory instrument designed for nucleic acid extraction. It performs automated sample preparation, allowing for efficient and reproducible extraction of DNA and RNA from a variety of sample types. The core function of the EasyMAG is to extract and purify nucleic acids in a streamlined and standardized process.

Automatically generated - may contain errors

Lab products found in correlation

6 protocols using easymag automated extractor

1

Comprehensive Respiratory Virus Screening

Check if the same lab product or an alternative is used in the 5 most similar protocols
Using 200 ul of nasopharyngeal swab material, nucleic acid was extracted by the bioMerieux easyMAG automated extractor. Specimens were tested using the xTAG Respiratory Virus Panel (RVP) assay for influenza A (subtype H1 and H3), influenza B, RSV (subtype A and B), parainfluenza (1–4), coronavirus (NL63, OC43, HKU1 and 229E), human metapneumovirus, entero-rhinovirus, and adenovirus as per the manufacturer's protocol (Luminex Molecular Diagnostics, Inc., Toronto, Ontario).
+ Open protocol
+ Expand
2

HHV-8 Detection in B Cells via PCR

Check if the same lab product or an alternative is used in the 5 most similar protocols
For the in vitro experiments, a total of 5×105 B cells and 500 µl of culture supernatant were collected post-HHV-8 exposure, pelleted, and assayed by PCR (50 (link), 51 (link)). Samples were treated with 1 µl DNase in 10 µl buffer (Sigma) for 15 min and then lysed in easyMAG buffer (NucliSENS). DNA was extracted with an easyMAG automated extractor (bioMérieux). Phocine herpesvirus was added as an internal control (52 (link)). DNA was mixed with a primer set specific for HHV-8 K8.1 (51 (link)), and the real-time PCR was done using a 7000, 7500, or ViiA7 ABI system (Applied Biosystems). B cells isolated from PBMC obtained from KS cases and controls were treated and tested for HHV-8 DNA as described above.
+ Open protocol
+ Expand
3

Viral RNA Extraction and RT-PCR Detection

Check if the same lab product or an alternative is used in the 5 most similar protocols
Viral RNA from samples were extracted using the easyMAG® automated extractor (BioMerieux, Quebec, Canada), according to manufacturer’s instructions. The input volumes for plasma and cerebrospinal fluid were 200 µl and the output volume was 55 µl. For urine the corresponding volumes were 200 µl and 110 µl respectively. A one-step RT-PCR was then performed employing TaqMan®Fast VirusOne-Step RT-PCR Master Mix (ABI) according to the protocol of Pabbaraju et al. [20 (link)].
+ Open protocol
+ Expand
4

Viral Nucleic Acid Extraction Using EasyMag

Check if the same lab product or an alternative is used in the 5 most similar protocols
Isolation of viral nucleic acid from control material and patient specimens was performed using an EasyMag automated extractor (bioMerieux, Durham, NC, USA) as previously described for the SRT-PCR assay.4 (link)
+ Open protocol
+ Expand
5

Automated Viral Nucleic Acid Extraction

Check if the same lab product or an alternative is used in the 5 most similar protocols
Isolation of viral nucleic acid from control material and patient specimens was performed using an EasyMag automated extractor (bioMerieux, Durham, NC) as previously described for the SRT-PCR assay.5
+ Open protocol
+ Expand
6

Multiplex Assay for Enterovirus Detection

Check if the same lab product or an alternative is used in the 5 most similar protocols
High and low viral loads of representative EVs from the different species including CV-A2, CV-A4, CV-A5, CV-A6, CV-A16 and EV-A71 for species A; CV-A9, CV-B2, CV-B3, CV-B4, CV-B5, E-4, E-9, E-18, E-25, E-30, E-82, EV-B86 and EV-B101 from species B; vaccine strains of PV-1, PV-2 and PV-3 from species C and EV-D68 and EV-D70 from species D were tested by the multiplex assay. Human PeVs tested by the assay included HPeV-1 and 3. All EVs were typed based on the partial sequence of the VP2 gene [4] (link), or of VP1 for CV-A5 and CV-B2 [13] (link).
To assess any competitive inhibition of target detection in cases with co-infections of EV and HPeVs, spiked samples were tested with different concentrations of both viruses. Cultured CV-B4 was spiked to give Ct values ranging from 20.17 to 32.47 and HPeV-3 was spiked to give Ct values ranging from 22.85 to 32.64 into universal transport media (UTM) and extracted using the using the easyMAG® automated extractor (BioMérieux, Durham, NC, USA). All extracts were tested by the single and multiplex assays.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!