The largest database of trusted experimental protocols

Eb 580s

Manufactured by Fujifilm
Sourced in Japan

The EB-580S is a lab equipment product manufactured by Fujifilm. It is a compact device designed for laboratory use. The core function of the EB-580S is to perform specific tasks required in a laboratory setting. Without further interpretation or extrapolation, the detailed description of this product is not available.

Automatically generated - may contain errors

3 protocols using eb 580s

1

Bronchoscopic Sampling of Airway Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
Bronchoscopy was performed 6 h after exposure with a flexible video bronchoscope (EB-580S, FUJIFILM Corporation, Japan). Topical anaesthesia with lidocaine was applied to the pharynx and bronchial tree. Bronchial wash (BW) 2 × 20 ml and Bronchoalveolar lavage (BAL) 3 × 60 ml with sterile saline were performed. Aspirates from BW and BAL were placed on ice in separate siliconized containers. Lavage samples were filtered through a nylon filter (100 µm) and centrifuged at 400 × g for 15 min. Cell pellets were resuspended in 0.9% NaCl at a concentration of 106 cells/mL. Differential cell counts were performed on cytocentrifuge preparations stained with May-Grünwald Giemsa. 400 cells per slide were counted. Images were taken with LeicaQWin V3 (Leica Q500IW; Leica, Cambridge, UK).
+ Open protocol
+ Expand
2

Flexible Bronchoscopy with Endobronchial Balloon

Check if the same lab product or an alternative is used in the 5 most similar protocols
Bronchoscopy was performed with a flexible bronchoscope of an EB-580T, EB-580S (Fujifilm, Tokyo, Japan), BF-1T290, BF1T-260, or BF-260 (Olympus, Tokyo, Japan). Patients underwent intravenous deep anaesthesia with pethidine, midazolam, or fentanyl, and 2% lidocaine was administered intratracheally. A flexible endotracheal tube (SACETT suction above cuff endotracheal tube 8.0–8.5 mm; Smiths Medical International Ltd., Minneapolis, MN, USA) was inserted for airway control. An endobronchial balloon (Fogarty® catheter, E-080-4F; Edwards Life-sciences, Irvine, CA, USA) was used for bronchial blockade and for haemostasis in all patients. If necessary, forceps (FB-15C-1, FB-231D; Olympus, Tokyo, Japan) and a guide sheath (K-201, K-203; Olympus, Tokyo, Japan) were used. A 1.4-mm 20-MHz radial probe (PB2020-M; Fujifilm or UM-S20-17S; Olympus) was also used in some patients for visualisation of lesions and blood vessels during determination of biopsy sites. All anticoagulant drugs were discontinued prior to the procedure as per guidelines [12 (link)].
+ Open protocol
+ Expand
3

Flexible Bronchoscopy for Lung Biopsy

Check if the same lab product or an alternative is used in the 5 most similar protocols
A flexible bronchoscope (EB-580T or EB-580S (Fujifilm, Tokyo, Japan), or BF-1T290, BF1T-260, or BF-260 (Olympus, Tokyo, Japan)) was used for bronchoscopies. A flexible endotracheal tube (SACETT Suction Above Cuff Endotracheal Tube 8.0–8.5 mm; Smiths Medical International, Minneapolis, Minnesota, USA) was used for airway control, and an endobronchial balloon (Fogarty catheter, E-080–4F; Edwards Life-Sciences, Irvine, California, USA) was used for bronchial blockade and haemostasis in all patients. R-EBUS was determined to be performed in conjunction with TBLC when high-resolution CT (HRCT) findings were indicative of DPLD and TBLC was performed for focal lesions in the bronchus, or when HRCT findings revealed several types of lesions, for example, ground-glass opacity (GGO) and consolidation in the same patient. A 1.4 mm, 20-MHz radial probe (PB2020-M; Fujifilm, or UM-S20-17S; Olympus) was used for R-EBUS. An epinephrine-saline mixture (1:10 000 epinephrine) was routinely administered at a dose of 2 mL just before and after TBLC.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!