Ls 50b luminescence fluorescence spectrophotometer

Manufactured by PerkinElmer
Sourced in Germany, United States

The LS-50B Luminescence fluorescence spectrophotometer is a high-performance instrument designed for accurate and reliable fluorescence measurements. It features a high-intensity, long-life xenon discharge lamp as the excitation source, providing a wide range of excitation wavelengths. The instrument is capable of recording emission spectra, excitation spectra, and time-resolved fluorescence measurements, making it a versatile tool for various applications in the field of fluorescence spectroscopy.

Automatically generated - may contain errors

3 protocols using ls 50b luminescence fluorescence spectrophotometer

1

Hippocampal Mitochondrial Membrane Potential

Check if the same lab product or an alternative is used in the 5 most similar protocols
An MMP assay kit (Beyotime Biotech, Shanghai, China) with fluorescent probe JC-1 was used to measure MMP of the hippocampal mitochondria. Incubation of the hippocampal mitochondria suspensions (0.5 mg protein/ml) was carried out with JC-1 reagent at 37°C for 15 min. The red fluorescence was measured at the excitation and emission wavelength of 525 and 590 mm, and green fluorescence was measured at the excitation and emission wavelength of 490 and 530 mm with the Perkin Elmer LS-50B Luminescence fluorescence spectrophotometer. The level of MMP was calculated by the ratio of red fluorescence to green fluorescence.
+ Open protocol
+ Expand
2

Absorption and Fluorescence Spectroscopy of Plastids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Ambient temperature absorption spectra of dark acclimated plastids/cells were determined in 1 ml WB (see Table 1) using an Ultrospec 8000 Spectrophotometer (GE healthcare). Relative absorbance was recorded at wavelength ranging from 350 to 750 nm with a bandwidth set to 1 nm. Fluorescence emission spectra were measured with a LS50B luminescence/fluorescence spectrophotometer using an excitation wavelength of 440 nm (Perkin Elmer; Hamburg, Germany). Plastids/cells corresponding to 20 �g Chl a were diluted in a total volume of 1 ml WB (see Table�1). Scan speed was kept at constant 150 nm/min.
+ Open protocol
+ Expand
3

Quantifying Hippocampal Mitochondrial ROS

Check if the same lab product or an alternative is used in the 5 most similar protocols
A ROS assay kit (Beyotime Biotech, Shanghai, China) with fluorescent probe DCFH-DA was used to measure the ROS level in the hippocampal mitochondria. Incubation of the hippocampal mitochondria suspensions (0.5 mg protein/ml) was carried out with 1.6 μM 2′, 7′-dichlorofluorescin diacetate (DCFH-DA) at 37°C for 10 min. The fluorescence was measured with the Perkin Elmer LS-50B Luminescence fluorescence spectrophotometer (California, USA) at the excitation and emission wavelength of 488 and 525 mm, respectively. Then, the mean fluorescence intensities in excitation/emission were quantified and compared.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!