The largest database of trusted experimental protocols

Magnetom verio 3.0 tesla

Manufactured by Siemens
Sourced in Germany

The Magnetom Verio 3.0 Tesla is a magnetic resonance imaging (MRI) system developed by Siemens. It operates at a magnetic field strength of 3.0 Tesla, which allows for high-quality imaging of the human body. The core function of the Magnetom Verio is to capture detailed anatomical images using this powerful magnetic field and advanced radio frequency technology.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using magnetom verio 3.0 tesla

1

Cardiac MRI Contrast Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Patients were scanned on Magnetom Avanto 1.5 Tesla or Magnetom Verio 3.0 Tesla magnetic resonance scanners (Siemens Medical Solutions, Erlangen, Germany). Scans were performed by dedicated CMR technologists. Gadolinium based contrast agents used for this study were gadopentetate dimeglumine (95.7%) and gadoversetamide (4.3%).
+ Open protocol
+ Expand
2

Comprehensive Breast MRI Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The breast MRI studies were performed on a MAGNETOM Verio 3.0 Tesla (T) scanner (Siemens Medical Solutions, Germany) using a dedicated 16-channel breast-specific phased array surface coil with patients in the prone position. Parameters for several sequences were listed as follows: T2-weighted imaging (T2WI): TR/TE, 4000/70 ms; slice thickness, 5 mm, 0.5 mm gap; field of view (FOV), 340 × 340; matrix, 448 × 448; NEX,1. T1WI (FLASH-3D): TR/TE, 3.6/2.1 ms; slice thickness, 1.2 mm, 0.2 mm gap; FOV, 340 × 340; matrix, 448 × 380; flip angle, 10°; NEX,0.7. EPI-DWI: TR/TE, 8300/85 ms; slice thickness, 4 mm, 2 mm gap; FOV, 360 × 147; matrix, 220 × 220; NEX,3; performed by fat suppression technology with b values of 0 and 1000 s/mm2. DCE-MRI was performed by the following parameters: TR/TE, 4.5/1.6 ms; flip angle, 10°; slice thickness,1 mm, 0.2 mm gap; matrix, 448 × 344; FOV, 340 × 340; NEX, 1. The first phase scan was conducted before the contrast agent was injected. After 25 s, Gd-DTPA (0.1–0.15 mmol/kg) was injected intravenously at a flow rate of 3.0 ml/s with a high-pressure syringe, followed by administration of a saline flush. The acquisition time was 487 s (77 s per dynamic sequence).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!