The largest database of trusted experimental protocols

Txo cryogenic probe

Manufactured by Bruker

The TXO cryogenic probe is a specialized instrument used for nuclear magnetic resonance (NMR) spectroscopy. It is designed to operate at cryogenic temperatures, typically between 4 and 20 Kelvin, in order to enhance the sensitivity and resolution of NMR measurements. The TXO cryogenic probe is capable of detecting and analyzing a wide range of chemical compounds and materials.

Automatically generated - may contain errors

2 protocols using txo cryogenic probe

1

Structural Dynamics of NTS-NTSR1 in Nanodiscs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Uniformly 15N-labeled NTS-NTSR1 in POPC/POPG (3:2) cNW9 nanodiscs at 200 μM alone and in complex with unlabeled Gαi1β1γ1 at a molar ratio of 5:1 were prepared as described above in NMR buffer (20 mM sodium phosphate (pH 6.9), 50 mM NaCl, 1 mM DTT, 0.5 mM EDTA, 10% D2O). Two-dimensional Transverse Relaxation Optimized Spectroscopy (TROSY) Heteronuclear Single Quantum Coherence (HSQC) were collected with 2000 scans, 200 increments at 45 °C on a Bruker 800-MHz spectrometer equipped with a TXO cryogenic probe. TROSY HSQC measurements were repeated for NTS-NTSR1-cND on an Agilent 700-MHz spectrometer to verify that NTS-NTSR1-cND stays intact after long data acquisition in the magnet at 45 ºC. Data were processed using the NMRPipe software package49 (link).
+ Open protocol
+ Expand
2

GPCR Dynamics in Nanodiscs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Uniformly 15 N-labeled NT-NTR1 in POPC/POPG (3:2) cNW9 nanodiscs at 200 mM alone and in complex with unlabeled Ga i1 b 1 g 1 at a molar ratio of 5:1 were prepared as described above in NMR buffer (20 mM sodium phosphate (pH 6.9), 50 mM NaCl, 1 mM DTT, 0.5 mM EDTA, 10% D 2 O). Two-dimensional Transverse Relaxation Optimized Spectroscopy (TROSY) Heteronuclear Single Quantum Coherence (HSQC) were collected with 2000 scans, 200 increments at 45 °C on a Bruker 800-MHz spectrometer equipped with a TXO cryogenic probe. TROSY HSQC measurements were repeated for NT-NTR1-cND on an Agilent 700-MHz spectrometer to verify that NT-NTR1-cND stays intact after long data acquisition in the magnet at 45 ºC. Data were processed using the NMRPipe software package 45 .
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!