Verios 460l xhr

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Verios 460L XHR is a high-resolution scanning electron microscope (SEM) designed for advanced imaging and analysis. It features a large specimen chamber and a high-resolution electron beam, enabling the capture of detailed images of a wide range of samples.

Automatically generated - may contain errors

4 protocols using verios 460l xhr

1

Electrochemical Characterization of N-Doped Porous Carbon

Check if the same lab product or an alternative is used in the 5 most similar protocols
We purchased almonds from the local market and obtained the shells. By mixing the stock solutions of 0.1 M NaAc and HAc, 0.1 M acetate buffer solution (HAc–NaAc) was prepared. Standard Pb(ii) solution (1000 mg L−1) was received from NCS Testing Technology Co. Ltd. (Beijing, China), and 5% Nafion stock solution was bought from Sigma-Aldrich (Shanghai, China). All chemical reagents received were of analytical grade. For all electrochemical tests, solutions were prepared in ultrapure water (≥18.2 MΩ cm).
A RST 5000C workstation (Zhengzhou Shiruisi Technology Co., Ltd. Zhengzhou, China) was used for electrochemical analysis. For carbonization and activation, we used a pipe furnace (GSL-1500X, Hefei Kejing Material Co., Ltd. Hefei, China). For the characterization of N-NPC samples, various techniques such as X-ray diffraction (X-ray D/max-2200vpc, Rigaku Corporation, Japan), Raman spectroscopy (confocal microprobe Raman system, HR800, Jobin Yvon, France), X-ray photoelectron spectroscopy (XPS, Thermo Scientific Escalab 250Xi, China), nitrogen sorption (NOVA 2000e, USA) and scanning electron microscopy (SEM, FEI Verios 460 L XHR Germany) were used.
+ Open protocol
+ Expand
2

Elemental Analysis via SEM-EDS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Elemental analysis was performed by using a scanning electron microscope (SEM), FEI Verios 460L XHR (extreme high resolution, Hillsboro, OR, USA), equipped with energy-dispersive X-ray spectroscopy (Thermo Fischer Scientific, Gloucester, UK).
+ Open protocol
+ Expand
3

Scanning Electron Microscopy and Elemental Analysis of Palladium Complex

Check if the same lab product or an alternative is used in the 5 most similar protocols
Scanning electronic microscopy (SEM) and elemental analysis of ι-Pd(OAc)2(TPPTS)2 were performed with lyophilized samples that were previously coated with gold, using FEI Verios 460L XHR (extreme high resolution, Hillsboro, OR, USA) scanning electron microscope, equipped with energy-dispersive X-ray spectroscopy (EDS, Oxford Instruments). The acceleration voltage was 20 kW.
+ Open protocol
+ Expand
4

Elemental Analysis of i-PdCl2(TPPTS)2 by SEM-EDS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Elemental analysis of i-PdCl2(TPPTS)2 was performed using scanning electron microscope (SEM), FEI Verios 460L XHR (extreme high resolution, Hillsboro, OR, USA), equipped with energy-dispersive X-ray spectroscopy (EDS, Oxford Instruments, Oxford, UK).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!