The largest database of trusted experimental protocols

Hemosil q f a thrombin

Manufactured by Werfen
Sourced in Spain

The HemosIL Q.F.A. Thrombin is a laboratory reagent used in the measurement of prothrombin time (PT) and activated partial thromboplastin time (aPTT) in clinical samples. It is a standardized thrombin preparation that serves as a component in coagulation testing procedures.

Automatically generated - may contain errors

2 protocols using hemosil q f a thrombin

1

Standardized Coagulation Assays and Antibody Testing

Check if the same lab product or an alternative is used in the 5 most similar protocols
Standardized coagulation assays in citrated (3.2%)-plasma were as follows: prothrombin time (PT, Medirox Owren's PT, Medirox, Nyköping, Sweden), fibrinogen (Clauss method, HemosIL Q.F.A. Thrombin, Werfen, Barcelona, Spain), and D-dimer (HemosIL D-Dimer HS 500). Antibodies (classes IgG, IgM and IgA) against PF4-heparin complexes were tested both with a gel agglutination rapid assay (ID-PaGIA Heparin/PF4 Antibody Test, Bio-Rad Laboratories, USA) and an enzyme-linked immunosorbent assay (ELISA) (Asserachrom HPIA, Diagnostica Stago, France). ELISA (Asserachrom HPIA, Diagnostica Stago) results were reported as percentage of absorbance related to reference sample. The reference sample was within the manufacturer specifications (stated on package insert, dependent on reagent lot). Percentage result is calculated (sample absorbance/reference absorbance). The interpretation of positivity is as follows: < 30 % of reference; negative, 30-50%, borderline positive, >50% positive, and >100% strongly positive.These results are referred below as anti-PF4 antibodies [1] (link). Cardiolipin and beta-2-glycoprotein-I IgG antibodies were analyzed using Phadia 250 immuno-analyzer and reagents (Sweden).
+ Open protocol
+ Expand
2

Coagulation Factors and Activity Assays

Check if the same lab product or an alternative is used in the 5 most similar protocols
Prothrombin time, fibrinogen and antithrombin were analysed on the ACL-TOP 750 (HemosIL ReadiPlasTin, HemosIL Q.F.A Thrombin, HemosIL Liquid Antithrombin, Werfen Barcelona, Spain). Von Willebrand antigen and activity were determined by immunoturbidimetric latex based assays (HemosIL von Willebrand Factor Antigen, HemosIL von Willebrand Ristocetin Cofactor assay; Werfen) on the ACL-TOP 700. Protein C was analyzed on ACL-TOP 700 (HemosIL Protein C, Werfen). ADAMTS13 was determined with the Technozym® ADAMTS-13 Activity ELISA kit (Technoclone, Wien, Austria). Von Willebrand antigen and activity are expressed in %. This is equivalent to IU/dL since these tests are calibrated against HemosIL Calibration Plasma (Werfen), which is traceable to the current International Standards.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!