The largest database of trusted experimental protocols

Myocor

Manufactured by Astellas Pharma
Sourced in Japan

Myocor is a laboratory equipment product designed for scientific research and experimentation. The core function of Myocor is to provide a controlled environment for conducting various experiments and analyses. The product's features and specifications are intended to support the specific needs of researchers and scientists in their work.

Automatically generated - may contain errors

2 protocols using myocor

1

Cardiac CT Angiography Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
We used a 256-slice (128 multi-detector row) CT scanner (Brilliance iCT; Philips Healthcare, Cleveland, Ohio, USA). All patients received 0.6 mg of nitroglycerin (Myocor; Astellas Pharma, Tokyo, Japan), and intravenous beta-blocker (Corebeta; landiolol hydrochloride, 0.125 mg/kg, Ono Pharmaceutical Co., Ltd., Tokyo, Japan), 5 min prior to the timing bolus scan, to reduce heart rate if the heart rate was > 75 beats per minutes, in the absence of contraindication. CorCTA was performed with iohexol (Omnipaque; 350 mg iodine/mL; Daiichi Sankyo, Tokyo, Japan) or with iopamidol (Iopamiron; 370 mg iodine/mL; Bayer Yakuhin, Osaka, Japan) at an injection rate of 5.0–5.5 mL/s for 10 s, followed by a saline flush (20 mL, 5.0–5.5 mL/s). The scan parameters were as follows: retrospective ECG-gated mode (heart rate > 60 beats/min) or prospective ECG-gated mode (heart rate ≤ 60 beats/min); tube voltage, 120 kV; effective tube current time-product, 800–1300 mAs/rotation with dose modulation; gantry rotation time, 0.27 s/rotation; collimation, 2 × 128 × 0.625 mm with a dynamic z-focal spot; 250-mm display field-of-view; 0.8/0.4-mm slice thickness/overlap; and 512 × 512 image matrix.
+ Open protocol
+ Expand
2

Dual-Source CT for Coronary Angiography

Check if the same lab product or an alternative is used in the 5 most similar protocols
Two dual-source CT scanners (SOMATOM Force or SOMATOM Definition Flash, Siemens Healthineers, Forchheim, Germany) were used according to the institutional scan protocol. First, a CAC score scan was performed using a prospective ECG-triggering axial scan mode (tube voltage, 120 kV; tube current time product, 80 mA/rotation for a 70-kg body weight as a reference, 3-mm slice thickness). Sublingual nitroglycerin (0.6 mg, Myocor; Astellas Pharma, Tokyo, Japan) was used before the coronary CTA examination, but no additional β-blockers or other heart rate-modifying medication were administered. Coronary CTA was performed using a retrospective ECG-triggering spiral scan mode or prospective ECG-triggering axial scan mode according to the scan heart rate. The scan parameters were as follows: gantry rotation time of 0.25 s/rotation (force), 0.28 s/rotation (definition flash); 90-, 100-or 120-kV tube voltage; 2×192×0.6 mm (force) or 2×128×0.6 mm (definition flash) detector collimation with z-flying focal spot; tube current 228 (145-292) mA per rotation with X-ray tube modulation that depended on patient size, variable pitch, and heart rate. Contrast material (iopamidol, 370 mg iodine/mL; On-Site CT-FFR Using ML Algorithm mine the total processing time.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!