The largest database of trusted experimental protocols

Bga12s hp gradients

Manufactured by Bruker
Sourced in Germany

The BGA12S-HP gradients is a high-performance gradient amplifier from Bruker. It is designed to provide precise and stable gradients for magnetic resonance imaging (MRI) and spectroscopy applications. The BGA12S-HP gradients offer high-speed switching and high-power output, enabling the generation of strong and uniform magnetic field gradients.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using bga12s hp gradients

1

High-Resolution MRI and Diffusion Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MRI was performed on a Bruker Biospec 9.4 T animal system with Bruker BGA12S-HP gradients (660 mT/m) using a 76 mm quadrature volume coil (Bruker Biospin, Ettlingen, Germany). Anatomical scans were performed with a RARE sequence with the following parameters; Echo time (TE) of 20 ms, RARE factor 8, 16 averages and a repetition time (TR) of 15204.8 ms. The slice thickness was 0.25 mm, in-plane resolution was 0.125 x 0.125 mm2 and the total number of slices was 80. Scan time for the anatomical data acquisition was 2 hrs 38 min.
Diffusion data was acquired with the 1-9-9 method outlined above and in [28 ]: 1 image with b = 0 ms/μm2, 9 images with b = 1 ms/μm2 and 9 images with b = 2.5 ms/μm2. The dMRI data was acquired with the following imaging parameters: TE = 27.387 ms, TR = 7500 ms, and diffusion timings δ/Δ = 6/14 ms. Data was acquired with an in-plane resolution of 0.25 x 0.25 mm2, and a slice thickness of 0.5 mm. Whole brain data was acquired (30 slices in total) with two averages. Scan time for the DKI protocol was 14 hours.
+ Open protocol
+ Expand
2

Kidney Fixation and Magnetic Resonance Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
All animals were euthanized and perfusion fixed using phosphate buffered saline (PBS) with 4% paraformaldehyde (PFA). Kidneys were then excised and stored in 4% PFA for weeks. Prior to imaging, each kidney was washed in PBS for 24 hrs to improve MRI signal by removal of excess fixative. For imaging, the kidney was placed in a tube with fluorinert (FC-770, 3M) in a manner so that the sample could not move. Imaging was performed on a Bruker Biospec 9.4 T animal system equipped with the Bruker BGA12S-HP gradients (660 mT/m) and a bore-mounted 15 mm quadrature coil (Bruker Biospin).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!