The largest database of trusted experimental protocols

1 n naoh

Manufactured by Carl Roth
Sourced in Germany

1 N NaOH is a common laboratory reagent used as a strong base. It has a concentration of 1 mole of sodium hydroxide per liter of solution.

Automatically generated - may contain errors

2 protocols using 1 n naoh

1

Quantifying NIS-mediated Iodide Uptake in HSP70B-NIS-MSCs

Check if the same lab product or an alternative is used in the 5 most similar protocols
NIS-mediated uptake of 125I in HSP70B-NIS- MSCs was measured as described previously 49 (link), 50 (link). Briefly, cells were seeded on 12-well plates and iodide uptake studies were performed at different time points (0 - 24 h) after heat treatment. Cells were incubated in Hanks' Balanced Salt solution (Gibco/Life Technologies, Carlsbad, California, USA), complemented with 10 µM NaI, 100 000 counts per minute (cpm) of Na125I/ml (PerkinElmer, Waltham, Massachusetts, USA) and 10 mM 4-(2-hydroxyethyl)- 1-piperazineethanesulfonic acid (HEPES; Sigma) (pH 7.3) for 45 min. The NIS-specific inhibitor KClO4 (100 mM; Merck Millipore, Burlington, Massachusetts, USA) was added to control wells to verify NIS specificity of uptake. After washing, cells were lysed in 1 N NaOH (Carl Roth GmbH + Co KG, Karlsruhe, Germany) for 15 min and trapped 125I was analyzed by γ-counting (Beckman Coulter GmbH, Krefeld, Germany). Results were normalized to cell survival (see below) and expressed as cpm / A620.
+ Open protocol
+ Expand
2

Evaluation of Antimicrobial Wound Dressings

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following wound dressings were selected for this study: alginate (Suprasorb® A, Lohmann & Rauscher GmbH & Co. KG, Germany) and alginate + ionic-Ag (Suprasorb® A + Ag, Lohmann & Rauscher GmbH & Co. KG, Germany), alginate + nano-Ag (Acticoat Absorbent, Smith & Nephew GmbH, Germany), sodium carboxymethylcellulose (CMC) (AQUACEL®, ConvaTec GmbH, Germany) CMC with Ag+ (AQUACEL® Ag, ConvaTec GmbH, Germany) as well as polyurethane (PU)-foam with TLC (UrgoCell®, URGO GmbH, Germany) and PU-foam with TLC/Ag+ (UrgoCell® silver, URGO GmbH, Germany). Active ingredients and wound dressing basic materials are specified in Table 2 according to the manufacturers’ descriptions.
Staphylococcus aureus ATCC 6538 and P. aeruginosa ATCC 27853 were obtained from the DSMZ (Deutsche Sammlung von Mikroorganismen und Zellkulturen, Germany). For cultivation of bacteria, special peptone and “lab-lemco” powder for preparation of caso-bouillon and bacteriological agar were purchased from Oxoid (UK). Columbia agar plates with 5 % sheep blood and MH2 agar plates were acquired from Biomeriéux (France).
0.9 % NaCl solution was purchased from Fresenius Kabi Deutschland GmbH (Germany). 1 N HCl, 1 N NaOH, and Tween 20 were obtained from Carl Roth GmbH (Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!