The largest database of trusted experimental protocols

Teflon foil

Manufactured by Goodfellow
Sourced in Germany

Teflon foil is a thin, flexible sheet made of polytetrafluoroethylene (PTFE), a synthetic fluoropolymer. It is known for its non-stick and heat-resistant properties. Teflon foil is primarily used as a protective layer or lining in various industrial and laboratory applications.

Automatically generated - may contain errors

2 protocols using teflon foil

1

Planar Lipid Bilayer Experiments

Check if the same lab product or an alternative is used in the 5 most similar protocols
Planar lipid bilayer experiments were done with a vertical bilayer setup (IonoVation) as described previously (Braun et al., 2014 (link)). A 1% hexadecane solution (Merck KGaA) in n-hexane (Carl Roth) was used for pretreating the Teflon foil (Goodfellow GmbH). The hexadecane solution (ca. 0.5 µl) was added to the rim of the hole (100 µm in diameter) in the Teflon foil with a bent Hamilton syringe. The experimental solution contained 100 mM KCl and was buffered to pH 7.0 with 10 mM HEPES/KOH. For bilayer formation, we used the following lipids from Avanti Polar Lipids (Fig. S1): 1,2-diphythanoyl-sn-glycero-3-phosphocholine (DPhPC), 1,2-diphythanoyl-sn-glycerol-3 phosphatidyl-serine (DPhPS), or n1,2-diphythanoyl-sn-glycero-3-phospho-(1′-rac-glycerol) (DPhPG). Cholesterol (Avanti Polar Lipids) was added to some DPhPC bilayers at a concentration of 0.15–25 mg/ml in n-pentane (Merck KGaA). Ion channel fluctuations were recorded with an EPC7 amplifier (List Medical) and digitized at 5 kHz after 1-kHz filtering with the LIH 1600 from HEKA Electronic. Data were analyzed with KielPatch (version 3.20 ZBM/2011) and Patchmaster (HEKA Electronic).
+ Open protocol
+ Expand
2

Planar Lipid Bilayer Formation

Check if the same lab product or an alternative is used in the 5 most similar protocols
These experiments were done either on a vertical bilayer set up (IonoVation, Osnabrück, Germany) as described previously [6 (link),22 (link)] or in horizontal bilayers using an eNPR amplifier, equipped with a BLM_chip flowcell (Elements srl, Cesena, Italy). A 1% hexadecane solution (MERCK KGaA, Darmstadt, Germany) in n-hexane (Carl ROTH, Karlsruhe, Germany) was used for pretreating the Teflon foil (Goodfellow GmbH, Hamburg, Germany). The hexadecane solution (ca. 0.5 μL) was added to the rim of the hole (100 μm in diameter) in the Teflon foil with a bent Hamilton syringe (Hamilton Company, Reno, NV, USA). The experimental solution contained 100 mM KCl and was buffered to pH 7.0 with 10 mM HEPES/KOH. As a lipid we used 1,2-diphythanoyl-sn-glycero-3-phosphocholine (DPhPC), 1,2-diphythanoyl-sn-glycerol-3 phosphatidyl-serine DPhPS, or n1,2-diphytanoyl-sn-glycero-3-phospho-(1′-rac-glycerol) DPhPG.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!