The largest database of trusted experimental protocols

R lactic acid

Manufactured by Merck Group

R-lactic acid is a chiral compound used in various laboratory applications. It is the naturally occurring isomer of lactic acid. R-lactic acid is a colorless, odorless, and water-soluble substance. It serves as a chemical building block and precursor in various research and industrial processes.

Automatically generated - may contain errors

2 protocols using r lactic acid

1

Synthesis and Characterization of Chiral Mo(VI) Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Na2MoO4·2H2O, R-lactic acid, 1,2,4-triazole and Na2S2O4 were purchased from Sigma. All solvents and chemicals were of commercially analytical grade. pH value was determined by PHB-8 digital pH meter. Elemental analyses (for C, H, and N) were performed with an Vario ELIII elemental analyzer. Spectra of vibrational circular dichroism for 1, 2 and {Na2[Δ-Mo*O2(R-lact*)2]}3 ∙ 13H2O, {Na2[Λ-Mo*O2(S-lact*)2]}3 ∙ 13H2O were recorded on a BioTools Chiral IR-2X spectrometer, where solid samples were mixed in KBr pellets at a mass ratio of 1:100, respectively. The VCD spectra of extracted FeMo-co and K5[Λ,Λ,Λ,Λ-Mo*4O11(R-Hhomocit*)2]Cl∙5H2O were measured by Bruker VCD/IRRAS module PMA 37 with MCT detector. To minimize the NMF left in the FeMo-co film, the samples were pumped for more than 8 h before the measurement. More physical measurements, preparations of [Λ/Δ-Mo*2O22-S)(μ2-O)(S-Hlact*)2(trz)2(trz)] (2), [Mo2O22-S)(μ2-O)(Hglyc)2(trz)2(H2O)] (3), {Na2[Δ-Mo*O2(R-lact*)2]}3 ∙ 13H2O and K5[Λ,Λ,Λ,Λ-Mo*4O11(R-Hhomocit*)2]Cl∙5H2O (21), gas adsorption and X-ray crystallography can be seen in the Part I of the Supplementary Methods of Supporting Information.
+ Open protocol
+ Expand
2

Synthesis and Characterization of Chiral Molybdenum Complexes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Na2MoO4·2H2O, R-lactic acid, 1,2,4-triazole and Na2S2O4 were purchased from Sigma. All solvents and chemicals were of commercially analytical grade. pH value was determined by PHB-8 digital pH meter. Elemental analyses (for C, H and N) were performed with an Vario ELIII elemental analyzer. Spectra of vibrational circular dichroism for 1, 2 and {Na2[Δ-Mo*O2(R-lact*)2]}3∙13H2O, {Na2[Λ-Mo*O2(S-lact*)2]}3∙13H2O were recorded on a BioTools Chiral IR-2X spectrometer, where solid samples were mixed in KBr pellets at a mass ratio of 1:100 respectively. The VCD spectra of extracted FeMo-co and K5[Λ,Λ,Λ,Λ-Mo*4O11(R-Hhomocit*)2]Cl∙5H2O were measured by Bruker VCD/IRRAS module PMA 37 with MCT detector. To minimize the NMF left in the FeMo-co film, the samples were pumped for more than 8 h before the measurement. More physical measurements, preparations of [Λ/Δ-Mo*2O22-S)(μ2-O)(S-Hlact*)2(trz)2(trz)] (2), [Mo2O22-S)(μ2-O)(Hglyc)2(trz)2(H2O)] (3), {Na2[Δ-Mo*O2(R-lact*)2]}3∙13H2O and K5[Λ,Λ,Λ,Λ-Mo*4O11(R-Hhomocit*)2]Cl∙5H2O (21), gas adsorption and X-ray crystallography can be seen in the Part I of the Supplementary Methods of Supporting Information.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!